Network Performance Monitor

Unable to add HPE Synergy 12000 as an SNMP Orion Node

SNMP test fails when adding a HPE Synergy 12000 Device as an Orion Node

First published date

1/25/2021 4:03 PM

Last published date

1/25/2021 4:03 PM

Overview

  • When Adding an Orion Node HPE SY 480 Gen10.  via SNMP 
  • SNMP test Fails on Orion web Console
  • The Devcie fails to respond to SNMP request from orion, Usng SNMP v1, V2 and V3  when using the SNMP walk tool. 

Product section

Network Performance Monitor

Cause


HPE Synergy 12000 Blade model does not support the required OIDs, required by Orion to add a Device via SNMP

1.3.6.1.2.1.1.1 sysdescr
1.3.6.1.2.1.1.2 sysobjectid
1.3.6.1.2.1.1.3 sysuptime
 

Resolution

  •  Device issue, please  contact the vendor and check if there is a firmware update that will allow you to poll the required OIDs.