Applications Systems
Difference in Hardware Health monitoring by manufacturer and polling method for physical servers in SAM
This article provides information on the different vendors and polling methods used when polling Hardware Health on physical servers. Depending on the device manufacturer, you may need to install additional software from third-party vendors.
First published date
Last published date
Overview
This article describes how data gathered by SAM's Hardware Health Monitoring feature varies based on the polling method used and the server manufacturer.
Before proceeding with this article, review these sections of the SAM Administrator Guide:
- Monitor hardware health in SAM
- Hardware health monitoring requirements
- Enable hardware health monitoring for nodes in SAM
See also the following sections of the Orion Platform Administrator Guide:
Product section
Resolution
For the latest information about supported devices, polling methods, and operating systems, see Hardware health monitoring requirements
This article includes the following sections:
- Data collected based on vendor and polling method
- HP
- HP SNMP Poller OIDs
- HP WMI Classes
- Dell
- Dell SNMP Poller OIDs
- Dell WMI Classes
- IBM
- IBM SNMP Poller OIDs
- IBM WMI Classes
- Verifying Source Data on the Server
- Verify SNMP OIDs using snmpwalk
- Verify WMI Pollers using WBEMTEST
Data collected based on vendor and polling method
This table shows the Hardware Health data that SAM can gather from monitored servers, based on polling method and manufacturer.
|
Manufacturer |
Polling method |
Chassis |
Temp. |
Fan |
Disk |
PS |
CPU |
Intrusion |
Memory |
Array |
Battery |
| Cisco UCS | ICMP | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | No | Yes |
| Nutanix | CLI | Yes | Yes | Yes | Yes | Yes | Yes | No | Yes | Yes | No |
|
HP | WMI |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
No |
|
HP | SNMP |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|
Dell | WMI |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
No |
|
Dell | SNMP |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
IBM | WMI |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
|
IBM | SNMP |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
No |
|
VMware | CIM poller |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
vCenter | API |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
No |
- Polling a Windows machine using a Windows Agent is the same with WMI.
- Polling a Linux machine using a Linux Agent is the same with SNMP.
SNMP OIDs and WMI Classes used for Polling
HP
HP SNMP Poller OIDs
Chassis:
|
OID = CPQSISYSSERIALNUM |
1.3.6.1.4.1.232.2.2.2.1 |
|---|---|
|
OID = cpqSiProductName |
1.3.6.1.4.1.232.2.2.4.2 |
Power Supply:
|
OID = CPQHEFLTTOLPOWERSUPPLYCHASSIS |
1.3.6.1.4.1.232.6.2.9.3.1.1 |
|---|---|
|
OID = cpqHeFltTolPowerSupplyCondition |
1.3.6.1.4.1.232.6.2.9.3.1.4 |
|
OID = cpqHeFltTolPowerSupplyMainVoltage |
1.3.6.1.4.1.232.6.2.9.3.1.6 |
|
OID = cpqHeFltTolPowerSupplyCapacityUsed |
1.3.6.1.4.1.232.6.2.9.3.1.7 |
|
OID = cpqHeFltTolPowerSupplyModel |
1.3.6.1.4.1.232.6.2.9.3.1.10 |
|
OID = cpqHeFltTolPowerSupplySerialNumber |
1.3.6.1.4.1.232.6.2.9.3.1.11 |
Power Meter:
|
OID = CPQHEPOWERMETERSUPPORT |
1.3.6.1.4.1.232.6.2.15.1 |
|---|---|
|
OID = cpqHePowerMeterCurrReading |
1.3.6.1.4.1.232.6.2.15.3 |
Memory:
|
OID = CPQSIMEMBOARDINDEX |
1.3.6.1.4.1.232.2.2.4.5.1.1 |
|---|---|
|
OID = cpqSiMemModuleSize |
1.3.6.1.4.1.232.2.2.4.5.1.3 |
|
OID = cpqSiMemModuleSerialNo |
1.3.6.1.4.1.232.2.2.4.5.1.10 |
|
OID = cpqHeResMemBoardIndex |
1.3.6.1.4.1.232.6.2.14.11.1.1 |
|
OID = cpqHeResMemModuleCondition |
1.3.6.1.4.1.232.6.2.14.11.1.5 |
Temperature:
|
OID = CPQHETEMPERATURECHASSIS |
1.3.6.1.4.1.232.6.2.6.8.1.1 |
|---|---|
|
OID = cpqHeTemperatureLocale |
1.3.6.1.4.1.232.6.2.6.8.1.3 |
|
OID = cpqHeTemperatureCelsius |
1.3.6.1.4.1.232.6.2.6.8.1.4 |
|
OID = cpqHeTemperatureCondition |
1.3.6.1.4.1.232.6.2.6.8.1.6 |
Fan:
|
OID = CPQHEFLTTOLFANCHASSIS |
1.3.6.1.4.1.232.6.2.6.7.1.1 |
|---|---|
|
OID = cpqHeFltTolFanIndex |
1.3.6.1.4.1.232.6.2.6.7.1.2 |
|
OID = cpqHeFltTolFanLocale |
1.3.6.1.4.1.232.6.2.6.7.1.3 |
|
OID = cpqHeFltTolFanPresent |
1.3.6.1.4.1.232.6.2.6.7.1.4 |
|
OID = cpqHeFltTolFanType |
1.3.6.1.4.1.232.6.2.6.7.1.5 |
|
OID = cpqHeFltTolFanCondition |
1.3.6.1.4.1.232.6.2.6.7.1.9 |
|
OID = cpqHeFltTolFanCurrentSpeed |
1.3.6.1.4.1.232.6.2.6.7.1.12 |
Cpu:
|
OID = CPQSECPUUNITINDEX |
1.3.6.1.4.1.232.1.2.2.1.1.1 |
|---|---|
|
OID = cpqSeCpuName |
1.3.6.1.4.1.232.1.2.2.1.1.3 |
|
OID = cpqSeCpuStatus |
1.3.6.1.4.1.232.1.2.2.1.1.6 |
|
OID = cpqSeCpuDesigner |
1.3.6.1.4.1.232.1.2.2.1.1.8 |
|
OID = cpqSeCpuSocketNumber |
1.3.6.1.4.1.232.1.2.2.1.1.9 |
Disk:
|
OID = CPQIDEATADISKCONTROLLERINDEX |
1.3.6.1.4.1.232.14.2.4.1.1.1 |
|---|---|
|
OID = cpqIdeAtaDiskModel |
1.3.6.1.4.1.232.14.2.4.1.1.3 |
|
OID = cpqIdeAtaDiskSerialNumber |
1.3.6.1.4.1.232.14.2.4.1.1.5 |
|
OID = cpqIdeAtaDiskCondition |
1.3.6.1.4.1.232.14.2.4.1.1.7 |
|
OID = cpqIdeAtaDiskCapacity |
1.3.6.1.4.1.232.14.2.4.1.1.8 |
|
OID = cpqIdeAtaDiskOsName |
1.3.6.1.4.1.232.14.2.4.1.1.15 |
|
OID = cpqDaPhyDrvCntlrIndex |
1.3.6.1.4.1.232.3.2.5.1.1.1 |
|
OID = cpqDaPhyDrvIndex |
1.3.6.1.4.1.232.3.2.5.1.1.2 |
|
OID = cpqDaPhyDrvModel |
1.3.6.1.4.1.232.3.2.5.1.1.3 |
|
OID = cpqDaPhyDrvStatus |
1.3.6.1.4.1.232.3.2.5.1.1.6 |
|
OID = cpqDaPhyDrvSize |
1.3.6.1.4.1.232.3.2.5.1.1.45 |
|
OID = cpqDaPhyDrvSerialNum |
1.3.6.1.4.1.232.3.2.5.1.1.51 |
|
OID = cpqDaPhyDrvLocationString |
1.3.6.1.4.1.232.3.2.5.1.1.64 |
Raid controller:
|
OID = CPQDACNTLRINDEX |
1.3.6.1.4.1.232.3.2.2.1.1.1 |
|---|---|
|
OID = cpqDaCntlrModel |
1.3.6.1.4.1.232.3.2.2.1.1.2 |
|
OID = cpqDaCntlrBoardCondition |
1.3.6.1.4.1.232.3.2.2.1.1.12 |
|
OID = cpqDaCntlrSerialNumber |
1.3.6.1.4.1.232.3.2.2.1.1.15 |
Raid Logical Drives:
|
OID = CPQDALOGDRVCNTLRINDEX |
1.3.6.1.4.1.232.3.2.3.1.1.1 |
|---|---|
|
OID = cpqDaLogDrvIndex |
1.3.6.1.4.1.232.3.2.3.1.1.2 |
|
OID = cpqDaLogDrvSize |
1.3.6.1.4.1.232.3.2.3.1.1.9 |
|
OID = cpqDaLogDrvCondition |
1.3.6.1.4.1.232.3.2.3.1.1.11 |
|
OID = cpqDaLogDrvOsName |
1.3.6.1.4.1.232.3.2.3.1.1.14 |
Battery:
|
OID = CPQDAACCELCNTLRINDEX |
1.3.6.1.4.1.232.3.2.2.2.1.1 |
|---|---|
|
OID = cpqDaAccelBattery |
1.3.6.1.4.1.232.3.2.2.2.1.6 |
HP WMI poller:
HP WMI Classes are polled from "root\HPQ" namespace:
- CIM_Chassis
- CIM_NumericSensor ( server from lab we use for testing is returning in this instance only temperature sensors. I am not sure if this will be common or is just this one machine case)
- HP_WinFan ( added to polling because NumericSensor returns only temperature sensor values)
- CIM_DiskDrive (HD sensor which do not return HealthState or Status)
- CIM_PowerSupply ( this class is returning not instances for lab server we use)
- HP_Processor - CPU information
- HP_MemoryModule – Memory information
Note: To verify that the data a server is providing is available, use WBEMTEST on the Orion Server, as described at the end of this article.
Dell
Dell SNMP Poller OIDs
Chassis:
|
OID = CHASSISMANUFACTURERNAME |
1.3.6.1.4.1.674.10892.1.300.10.1.8 |
|---|---|
|
OID = chassisModelName |
1.3.6.1.4.1.674.10892.1.300.10.1.9 |
|
OID = chassisServiceTagName |
1.3.6.1.4.1.674.10892.1.300.10.1.11 |
|
OID = cpqSiSysSerialNum |
1.3.6.1.4.1.232.2.2.2.1 |
|
OID = cpqSiProductName |
1.3.6.1.4.1.232.2.2.4.2 |
Power Supply:
|
OID = POWERSUPPLYCHASSISINDEX |
1.3.6.1.4.1.674.10892.1.600.12.1.1 |
|---|---|
|
OID = powerSupplyStatus |
1.3.6.1.4.1.674.10892.1.600.12.1.5 |
|
OID = powerSupplyOutputWatts |
1.3.6.1.4.1.674.10892.1.600.12.1.6 |
|
OID = powerSupplyType |
1.3.6.1.4.1.674.10892.1.600.12.1.7 |
|
OID = powerSupplyLocationName |
1.3.6.1.4.1.674.10892.1.600.12.1.8 |
Voltage:
|
OID = VOLTAGEPROBECHASSISINDEX |
1.3.6.1.4.1.674.10892.1.600.20.1.1 |
|---|---|
|
OID = voltageProbeStatus |
1.3.6.1.4.1.674.10892.1.600.20.1.5 |
|
OID = voltageProbeReading |
1.3.6.1.4.1.674.10892.1.600.20.1.6 |
|
OID = voltageProbeType |
1.3.6.1.4.1.674.10892.1.600.20.1.7 |
|
OID = voltageProbeLocationName |
1.3.6.1.4.1.674.10892.1.600.20.1.8 |
|
OID = voltageProbeDiscreteReading |
1.3.6.1.4.1.674.10892.1.600.20.1.16 |
Amperage:
|
OID = AMPERAGEPROBECHASSISINDEX |
1.3.6.1.4.1.674.10892.1.600.30.1.1 |
|---|---|
|
OID = amperageProbeStatus |
1.3.6.1.4.1.674.10892.1.600.30.1.5 |
|
OID = amperageProbeReading |
1.3.6.1.4.1.674.10892.1.600.30.1.6 |
|
OID = amperageProbeType |
1.3.6.1.4.1.674.10892.1.600.30.1.7 |
|
OID = amperageProbeLocationName |
1.3.6.1.4.1.674.10892.1.600.30.1.8 |
|
OID = amperageProbeDiscreteReading |
1.3.6.1.4.1.674.10892.1.600.30.1.16 |
Memory:
|
OID = MEMORYDEVICECHASSISINDEX |
1.3.6.1.4.1.674.10892.1.1100.50.1.1 |
|---|---|
|
OID = memoryDeviceStatus |
1.3.6.1.4.1.674.10892.1.1100.50.1.5 |
|
OID = memoryDeviceLocationName |
1.3.6.1.4.1.674.10892.1.1100.50.1.8 |
|
OID = memoryDeviceSize |
1.3.6.1.4.1.674.10892.1.1100.50.1.14 |
|
OID = memoryDeviceSerialNumberName |
1.3.6.1.4.1.674.10892.1.1100.50.1.23 |
Temperature:
|
OID = TEMPERATUREPROBECHASSISINDEX |
1.3.6.1.4.1.674.10892.1.700.20.1.1 |
|---|---|
|
OID = temperatureProbeStatus |
1.3.6.1.4.1.674.10892.1.700.20.1.5 |
|
OID = temperatureProbeReading |
1.3.6.1.4.1.674.10892.1.700.20.1.6 |
|
OID = temperatureProbeType |
1.3.6.1.4.1.674.10892.1.700.20.1.7 |
|
OID = temperatureProbeLocationName |
1.3.6.1.4.1.674.10892.1.700.20.1.8 |
Fan:
|
OID = COOLINGDEVICECHASSISINDEX |
1.3.6.1.4.1.674.10892.1.700.12.1.1 |
|---|---|
|
OID = coolingDeviceStatus |
1.3.6.1.4.1.674.10892.1.700.12.1.5 |
|
OID = coolingDeviceReading |
1.3.6.1.4.1.674.10892.1.700.12.1.6 |
|
OID = coolingDeviceType |
1.3.6.1.4.1.674.10892.1.700.12.1.7 |
|
OID = coolingDeviceLocationName |
1.3.6.1.4.1.674.10892.1.700.12.1.8 |
Cpu:
|
OID = PROCESSORDEVICECHASSISINDEX |
1.3.6.1.4.1.674.10892.1.1100.30.1.1 |
|---|---|
|
OID = processorDeviceIndex |
1.3.6.1.4.1.674.10892.1.1100.30.1.2 |
|
OID = processorDeviceStatus |
1.3.6.1.4.1.674.10892.1.1100.30.1.5 |
|
OID = processorDeviceVersionName |
1.3.6.1.4.1.674.10892.1.1100.30.1.16 |
Disk:
|
OID = ARRAYDISKNUMBER |
1.3.6.1.4.1.674.10893.1.20.130.4.1.1 |
|---|---|
|
OID = arrayDiskName |
1.3.6.1.4.1.674.10893.1.20.130.4.1.2 |
|
OID = arrayDiskSerialNo |
1.3.6.1.4.1.674.10893.1.20.130.4.1.7 |
|
OID = arrayDiskLengthInMB |
1.3.6.1.4.1.674.10893.1.20.130.4.1.11 |
|
OID = arrayDiskComponentStatus |
1.3.6.1.4.1.674.10893.1.20.130.4.1.14 |
Raid controller:
|
OID = CONTROLLERNUMBER |
1.3.6.1.4.1.674.10893.1.20.130.1.1.1 |
|---|---|
|
OID = controllerName |
1.3.6.1.4.1.674.10893.1.20.130.1.1.2 |
|
OID = controllerComponentStatus |
1.3.6.1.4.1.674.10893.1.20.130.1.1.38 |
Chassis Intrusion:
|
OID = SYSTEMSTATECHASSISINTRUSIONSTATUSCOMBINED |
1.3.6.1.4.1.674.10892.1.200.10.1.30 |
|---|
Battery:
|
OID = BATTERYCHASSISINDEX |
1.3.6.1.4.1.674.10892.1.600.50.1.1 |
|---|---|
|
OID = batteryIndex |
1.3.6.1.4.1.674.10892.1.600.50.1.2 |
|
OID = batteryStatus |
1.3.6.1.4.1.674.10892.1.600.50.1.5 |
|
OID = batteryLocationName |
1.3.6.1.4.1.674.10892.1.600.50.1.7 |
Dell WMI poller
Dell WMI Classes are polled from the "root\cimv2\dell" namespace:
- CIM_Chassis
- CIM_Tachometer - Fans
- CIM_TemperatureSensor - Temperature
- DELL_PowerConsumptionWattsSensor - PoweSupply
- DELL_PowerConsumptionAmpsSensor - PoweSupply
- CIM_VoltageSensor - PoweSupply
- CIM_Processor
- CIM_PhysicalMemory
To verify the data a server is providing is available use WBEMTEST on the Orion Server. Steps at then end of the document.
IBM
IBM SNMP Poller OIDs
Chassis:
|
OID = IBMPSGCOMPUTERSYSTEMDETAILSKEYINDEX |
1.3.6.1.4.1.2.6.159.1.1.60.3.1.1 |
OID = cpqSiSysSerialNum |
1.3.6.1.4.1.232.2.2.2.1 |
|---|---|---|---|
|
OID = iBMPSGComputerSystemDetailsModel |
1.3.6.1.4.1.2.6.159.1.1.60.3.1.8 |
1.3.6.1.4.1.2.6.159.1.1.60.3.1.1 |
1.3.6.1.4.1.2.6.159.1.1.60.3.1.1 |
|
OID = iBMPSGComputerSystemDetailsSerialNumber |
1.3.6.1.4.1.2.6.159.1.1.60.3.1.10 |
1.3.6.1.4.1.2.6.159.1.1.60.3.1.1 |
1.3.6.1.4.1.2.6.159.1.1.60.3.1.1 |
Power Supply:
|
OID = IBMPSGVOLTAGESENSORKEYINDEX |
1.3.6.1.4.1.2.6.159.1.1.80.2.1.1 |
|---|---|
|
OID = iBMPSGVoltageSensorCurrentReading |
1.3.6.1.4.1.2.6.159.1.1.80.2.1.2 |
|
OID = iBMPSGVoltageSensorStatus |
1.3.6.1.4.1.2.6.159.1.1.80.2.1.21 |
Memory:
|
OID = IBMSYSTEMPHYSICALMEMORYKEYINDEX |
1.3.6.1.4.1.2.6.159.1.1.120.1.1.1 |
|---|---|
|
OID = ibmSystemPhysicalMemoryCapacity |
1.3.6.1.4.1.2.6.159.1.1.120.1.1.11 |
|
OID = ibmSystemPhysicalMemoryBankLabel |
1.3.6.1.4.1.2.6.159.1.1.120.1.1.12 |
|
OID = ibmSystemPhysicalMemorySerialNumber |
1.3.6.1.4.1.2.6.159.1.1.120.1.1.16 |
|
OID = ibmSystemPhysicalMemoryStatus |
1.3.6.1.4.1.2.6.159.1.1.120.1.1.17 |
Temperature:
|
OID = IBMPSGTEMPERATURESENSORKEYINDEX |
1.3.6.1.4.1.2.6.159.1.1.80.1.1.1 |
|---|---|
|
OID = iBMPSGTemperatureSensorCurrentReading |
1.3.6.1.4.1.2.6.159.1.1.80.1.1.2 |
|
OID = iBMPSGTemperatureSensorStatus |
1.3.6.1.4.1.2.6.159.1.1.80.1.1.21 |
Fan:
|
OID = IBMPSGTACHOMETERKEYINDEX |
1.3.6.1.4.1.2.6.159.1.1.80.5.1.1 |
|
|---|---|---|
|
OID = iBMPSGTachometerCurrentReading |
1.3.6.1.4.1.2.6.159.1.1.80.5.1.2 |
|
|
OID = iBMPSGTachometerStatus |
1.3.6.1.4.1.2.6.159.1.1.80.5.1.20 |
|
Cpu:
|
OID = IBMSYSTEMPROCESSORKEYINDEX |
1.3.6.1.4.1.2.6.159.1.1.140.1.1.1 |
|---|---|
|
OID = ibmSystemProcessorManufacturer |
1.3.6.1.4.1.2.6.159.1.1.140.1.1.2 |
|
OID = ibmSystemProcessorUniqueID |
1.3.6.1.4.1.2.6.159.1.1.140.1.1.13 |
|
OID = ibmSystemProcessorStatus |
1.3.6.1.4.1.2.6.159.1.1.140.1.1.15 |
Disk:
|
OID = AUSDEVICEINDEX |
1.3.6.1.4.1.795.14.1.400.1.1.1 |
|---|---|
|
OID = ausDeviceUniqueId |
1.3.6.1.4.1.795.14.1.400.1.1.2 |
|
OID = ausDeviceTypeGroup |
1.3.6.1.4.1.795.14.1.400.1.1.5 |
|
OID = ausDeviceVendor |
1.3.6.1.4.1.795.14.1.400.1.1.6 |
|
OID = ausDeviceModel |
1.3.6.1.4.1.795.14.1.400.1.1.7 |
|
OID = ausDeviceSerialNumber |
1.3.6.1.4.1.795.14.1.400.1.1.9 |
|
OID = ausDeviceStatus |
1.3.6.1.4.1.795.14.1.400.1.1.11 |
|
OID = ausStorageDeviceIndex |
1.3.6.1.4.1.795.14.1.410.1.1.1 |
|
OID = ausStorageDeviceFormattedCapacity |
1.3.6.1.4.1.795.14.1.410.1.1.3 |
Raid controller:
|
OID = AUSCONTROLLERINDEX |
1.3.6.1.4.1.795.14.1.201.1.1.1 |
|---|---|
|
OID = ausControllerUniqueId |
1.3.6.1.4.1.795.14.1.201.1.1.2 |
|
OID = ausControllerVendor |
1.3.6.1.4.1.795.14.1.201.1.1.3 |
|
OID = ausControllerModel |
1.3.6.1.4.1.795.14.1.201.1.1.4 |
|
OID = ausControllerSerialNumber |
1.3.6.1.4.1.795.14.1.201.1.1.6 |
|
OID = ausControllerStatus |
1.3.6.1.4.1.795.14.1.201.1.1.15 |
|
OID = ausArrayIndex |
1.3.6.1.4.1.795.14.1.1000.1.1.1 |
|
OID = ausArrayName |
1.3.6.1.4.1.795.14.1.1000.1.1.2 |
|
OID = ausArrayCapacity |
1.3.6.1.4.1.795.14.1.1000.1.1.3 |
|
OID = ausArrayStatus |
1.3.6.1.4.1.795.14.1.1000.1.1.11 |
IBM WMI poller
Classes polled already by this poller from "root\IBMSD" namespace:
- CIM_Chassis
- CIM_NumericSensor
- IBMPSG_PhysicalMemory
- IBMPSG_DiskDrive
- CIM_PowerSupply
- CIM_Battery
- IBMPSG_Processor
- IBMPSG_SystemEnclosure
To verify the data a server is providing is available use WBEMTEST on the Orion Server.
Verify Source Data on the Server
To verify SNMP OIDs using SNMP Walk :
- Remote Desktop to the Orion Server
- Open SNMPwalk.exe in the Orion installation directory. (The default path is C:\Program Files (x86)\Solarwinds\Orion)
- Fill out the IP Address and Community String
- Click Scan
- Search the resulting file for the OIDs listed above for the related vendor.
To verify WMI Pollers using WBEMTEST :
- Remote Desktop to the Orion Server
- Run > wbemtest
- Connect
- Namespace: (Differs based on Vendor from above)
\\IPAddressofTargetServer\root\HPQ
\\IPAddressofTargetServer\root\cimv2\dell
\\IPAddressofTargetServer\root\IBMSD - Provide credentials under User and Password.
- Leave Authority blank
- Click Connect
- Click Query
- Generate a query based on the classes from above to verify the information.
Example:-- Scripts are not supported under any SolarWinds support program or service. -- Scripts are provided AS IS without warranty of any kind. SolarWinds further -- disclaims all warranties including, without limitation, any implied warranties -- of merchantability or of fitness for a particular purpose. The risk arising -- out of the use or performance of the scripts and documentation stays with you. -- In no event shall SolarWinds or anyone else involved in the creation, -- production, or delivery of the scripts be liable for any damages whatsoever -- (including, without limitation, damages for loss of business profits, business -- interruption, loss of business information, or other pecuniary loss) arising -- out of the use of or inability to use the scripts or documentation. SELECT * FROM CIM_Chassis
URLs used by SolarWinds to poll Warranty information.
HP : https://support.hpe.com/hpsc/wc/public/home
Dell: https://www.dell.com/support/home/en-ph
IBM: The warranty information moved from IBM website to Lenovo website. https://support.lenovo.com/us/en/systemxwarrantylookup