Network Management

High Availability: Cannot enable HA pool due product version mismatch

This article provides information when you have recently upgraded Orion and Cannot enable HA pool due to product version mismatch on one of the pollers set

First published date

9/25/2020 8:55 AM

Last published date

2/8/2022 12:18 AM

Overview

This article will help you to correct the issue where the HA Main Pool will remain disabled due to product version mismatch for Orion product versions 

Product section

Network Performance Monitor

Cause

Permission issues on the installer directory could cause such issues 
Orion Modules/versions/hotfixes are mismatched between the Pool

Resolution

  • Run the Orion Permission Checker
  • Go to the Installer directory (C:\ProgramData\SolarWinds\Installers)  and verify if you are able to access
  • Allow permanent access to the drives 
  • Repair SolarWinds Orion Core Service and complete the Configuration Wizard 
  • Verify you do not have any Error running above operation 
Make sure that the Orion Modules, versions, and hotfixes are the same between the Primary Server and HA Standby Server within the Pool.

Example of a Product mismatch:
mismatch.PNG