Applications Systems

Windows service monitors error: Quota violation

When attempting to monitor a large amount of Windows Service Monitors with WMI in one template, it returns a Quota Violation Error. Server & Application Monitor SAM

First published date

10/10/2018 6:23 PM

Last published date

6/25/2020 9:57 PM

Overview

When attempting to monitor a large amount of Windows services in one Application Monitor, all of the monitors return the following error:

Unexpected error: Quota Violation

Product section

Server Application Monitor

Cause

This occurs when SAM Polling bulk polls all of the services in one WMI query. For example, if a template has 50 service monitors then it will utilize one WMI query.

Resolution

Switch the polling method of all Windows Service Monitors to RPC:

  1. Edit the Application Monitor.
  2. Select all the Windows service monitor components.
  3. Click Multi-Edit.
  4. Change Fetching Method to RPC (Remote Procedure Call).