When adding a node polled by an Orion Remote Collector, UnDPs are not assigned
When you add a node for monitoring by the Orion Platform, specify an Orion Remote Collector (ORC) as the polling engine and assign Universal Device Pollers (UnDPs) to the node, the UnDPs are not assigned. Use an alternative method to assign the UnDPs to the node.
First published date
Last published date
Overview
Note: The ORC feature was introduced in Orion Platform 2020.2.1 and requires NAM 2020.2.1.
Product section
Cause
Resolution
- Start the Universal Device Poller tool, right-click the poller and click Assign. Select the node you want to poll the poller on. See Select Orion Platform nodes or interfaces to poll a custom statistic.
- In the Orion Web Console, go to the Node Details view and click Pollers in the Management widget. Assign the UnDPs to the node.