Applications Systems

WMI connections failing in SAM

This article discusses how to resolve an issue where WMI-based monitors fail to connect to a target server.

First published date

10/10/2018 6:44 PM

Last published date

3/30/2022 7:55 AM

Overview

WMI-based monitors fail to connect to target system.

Product section

Server Application Monitor

Cause

The System hosting the SAM installation is not trusted.
This issue can occur if the target server does not recognize the Orion server as a trusted system.

Resolution

  1. Log into the target server being monitor.
  2. From the Start menu, navigate to Windows Administrative Tools > Local Security Policy.
  3. Click Network List Manager Policies.
  4. Double-click All Networks.
  5. Set Network Location to "User can change Location".
  6. Click OK.