Unable to run DISA STIG policy reports on NCM
When running some Network Configuration Manager (NCM) DISA STIG reports, there is an error on updating. This article describes the resolution.
First published date
Last published date
Overview
Product section
Cause
Resolution
- From the Orion Web Console, open the NCM compliance page.
- Identify one of the Dist STIG reports displaying ERROR in the Last Update Column.
- Go to Manage Reports in upper right corner of the same page.
- Select the Report identified in Step 2 and select Edit.
Note: Using the search option will be useful to narrow the hunt.
-
Take note of which policies are in the report. They will show in the Assigned Policies Column.
-
Return to the Manage Policy Reports screen and go to the Manage Policies tab.
-
Select the policy or one of the policies in the report and click Edit.
In NCM 7.5 you are likely to see something like this:
or if imported from Thwack, may look like this:
- in the first example, click on the blue hyperlink for all nodes. Use this to select the nodes, be it All nodes, Select nodes, or Dynamic selection. It is recommended to use Dynamic selection and use a rule relevant to the nodes you need this policy to run against (do not use Nodeid).
- When using Dynamic selection, select a valid option, such as Vendor, and select a valid vendor, such as Cisco.
- Click Submit to save the changes.
- Repeat this process for all applicable reports.
- From the compliance page, click Update all.