Network Management
Unable to connect to polling engine "xyz" on relevant server. Verify that NCM 7.x.x is installed
If there are devices connected to NCM on an Additional Poller, and the NCM plugin is not installed, NCM would not be able to access these devices. The following error is received: Unable to connect to polling engine "xyz" on relevant server. Verify that NCM 7.x.x is installed
First published date
Last published date
Overview
If there are devices connected to NCM on an Additional Poller, and the NCM plugin is not installed, NCM would not be able to access these devices. The following error is received:
Unable to connect to polling engine "xyz" on relevant server. Verify that NCM 7.x.x is installed
Note: NCM is able to leverage an Additional polling engine for Scalability purposes.
Product section
Cause
When NCM is using an Orion Core structure where Additional polling engines are part of the environment, it is mandatory to install the Individual polling engine plugin on the Orion Additional Polling engines. These are included in the Orion Additional Component Download and not the NCM installer download.
Resolution
- Download the Additional Polling Engine Installer from the SolarWinds Customer Portal.
- Save it on the Additional Polling Engine server for both the Core and the NCM additional Polling engine.
- On the server that is (or intended) to be an Additional Polling Engine, install the Orion additional Poller, if it is not already installed.
- Verify that the installation is completed and it is listed in the Settings on the Orion Web Console in the Details >Polling Engines.
- Register the Components that do not require a license and complete the Orion Configuration Wizard.
- Repeat this for all pollers.
- Verify a config can be downloaded for at least one device on each Orion Polling Engine.