Unable to access automation servers from the primary server console
This article describes an issue where you are unable to browse and access the Patch Manager and the 'automation server unable to access dgsrpcinterface createsession failed SmoException' error is found in the EWDGS logs.
First published date
Last published date
Overview
This article describes an issue where you are unable to browse and access the Patch Manager Console and the following error is found in the EWDGS logs:
2017/07/06 13:23:29:412 PID: 7104 TID: 6168 [ERROR] SMO InnerException: An exception occurred while executing a Transact-SQL statement or batch.
at Microsoft.SqlServer.Management.Smo.SqlSmoObject.AlterImpl()
at EminentWare.DataQueryAdapters.CMDBManager.SetAutoCloseOff()
2017/07/06 13:55:57:567 PID: 7104 TID: 4948 [ERROR] MonitoringAndSychronizationRequest::ExecuteDiagnosticsRequest(auto) to server: V1TSSPM03 failed. Message: Communication failure.
The RPC server is unavailable.
Details: dgsrpcinterface::createsession failed!
Stack Trace: at EminentWare.Core.Client.RPC.rpcclient.createsession(String operation, String subsystem, String taskid)
at EminentWare.DataGridServer.Executive.MonitoringAndSychronizationRequest.ExecuteDiagnosticsRequest()
Product section
Resolution
- Delete the EminentWare Server certificate ONLY from the Trusted root certificate store on automation servers.
- Repair the automation server from Add or Remove programs.
- Run the Patch Manager configuration wizard to completion.
- Run the Patch Manager server wizard to authenticate the primary server from the automation server.
- Run
services.mscand start the EminentWare service.