Network Management
There was no response from the UDT Service Engine located at "Server: 'XXXX' Port: '17777' EngineID: 'X'"
The following error is received in UDT: There was no response from the UDT Service Engine located at "Server: 'XXXX' Port: '17777' EngineID: 'X'"
First published date
Last published date
Overview
The following error is received in UDT:
There was no response from the UDT Service Engine located at "Server: 'XXXX' Port: '17777' EngineID: 'X'"
Product section
Cause
Resolution
- Navigate to Program Files (x86)\SolarWinds\Orion\UDT\SolarWinds.UDT.BusinessLayer.dll.
- Right-click the Solarwinds.UDT.BusinessLayer.dll file and select Properties.
- Open the Security option in the General tab. If you see a message that the file might be blocked, click the Unblock button.
- Restart the SolarWinds services using the SolarWinds Platform Service Manager.
If the solution above didn't work, then follow the steps below (encountered after upgrading to UDT version 2019.4):
- Stop all the SolarWinds services.
- Navigate to Program Files (x86)\SolarWinds\Orion\UDT.
- Sort the files by Date modified.
- Cut all the files before year 2019.
- Start the SolarWinds services.
If these actions don't resolve the issue, restart the Orion Module Engine and confirm the UDT Business Layer Plugin starts successfully in: C:\ProgramData\Solarwinds\Logs\Orion\BusinessLayerHost.log