Network Management
The settings property Toolset.ToolsetSummaryViewID was not found error in the SolarWinds 2022.2 and below
How to fix the "settings property Toolset.ToolsetSummaryViewID was not found" error when you log in to the Orion Web Console.
First published date
Last published date
Overview
Product section
Cause
- An old version of DLL's from Toolset application interferes with Orion.
- A known issue in 2022.3 RC3
Resolution
- Repair or completely remove Toolset from Add / Remove programs.
- Run Orion Configuration Wizard when prompted.
- Fixed in 2022.3 GA. If you are running an RC version, please upgrade either through the web console at Settings > My Orion Deployment > Updates or by using the installer available in the customer portal.