Applications Systems
The number of monitored instances exceeds the supported maximum for a single instance of DPA
Database Performance Analyzer (DPA) warns if you monitor more than 250 instances on a single DPA server. If your server is capable of handling more than 250 instances, you can suppress this warning message.
First published date
Last published date
Overview
Product section
Resolution
To get past the 250 instance warning, do the following:
- Log in to the DPA server.
- Open the system.properties files in a text editor:
<DPAHome>/iwc/tomcat/ignite_config/idc/system.properties - Add the following line:
com.confio.idc.level.four.max.databases=300