Applications Systems
The Web Console is unable to communicate with the SAM Service Engine
When clicking on any SAM entities in Orion, the following error is received: The Web Console is unable to communicate with the SAM Service Engine. Error 17777.
First published date
Last published date
Overview
When clicking on a SAM entity in the Orion Web Console, one of the following messages appears:
The Web Console is unable to communicate with the SAM Service Engine.
or,
There was no response from the SAM Service Engine located at "localservername:17777."
Product section
Cause
Resolution
- Restart the NET TCP port sharing service
- Restart the Orion Services using the Orion Service Manager
- Wait at least five minutes for polling to occur
If this does not resolve the issue, check the Engines and Websites table in Database Manager on the main Orion server.
- In the Orion Service Manager, stop all Orion services using Start and stop Orion services.
- Enable table editing.
- Remove any old websites or engines from both tables.
- Restart Orion services.
- Wait at least five minutes for polling to occur.
Disclaimer: Please note, any content posted herein is provided as a suggestion or recommendation to you for your internal use. This is not part of the SolarWinds software or documentation that you purchased from SolarWinds, and the information set forth herein may come from third parties. Your organization should internally review and assess to what extent, if any, such custom scripts or recommendations will be incorporated into your environment. You elect to use third party content at your own risk, and you will be solely responsible for the incorporation of the same, if any.