Test failed with "Unknown" status on xxxxx Node Provider load failure

When testing a Windows Service Monitor, the following error appears: Test failed with "Unknown" status on xxxxx Node Provider load failure

First published date

10/9/2018 8:12 PM

Last published date

9/8/2025 4:53 PM

Overview

When testing a Windows Service Monitor, the following error appears:

Test failed with "Unknown" status on xxxxx Node
Provider load failure

Product section

Server Application Monitor

Cause

This happens when you try to run the template in x64 bit polling mode when the target server is a 32-bit machine.

Resolution

  1. Open the SolarWinds Platform Web Console.

  2. Click Settings > SAM Settings > Manage Templates.

  3. Edit the Template in question.

  4. Expand Advanced.

  5. Switch "Platform to run polling job on:" to x86.