Storage Resource Monitor was able to connect to the device but no compatible arrays were found.

Product section

Storage Resource Monitor

Cause

This issue can be triggered by any of the following issues:

  • An incorrect storage array type was chosen.
  • The device was unavailable during discovery, or the SMI-S provider itself could be unavailable. To test this you can use either the built-in Solarwinds CIM Browser tool from the SolarWinds Platform server: <InstallFolder>\SolarWinds\Orion\Solarwinds.CIMBrowser, or you can use the TestSMIProvider.bat file found in <installFolder>\ECIM\ECOM\bin  on the SRM server to ensure connectivity.
  • The provider is installed, but is not configured correctly to scan any devices. For more information on configuring your array and provider, see Add storage arrays to SRM .
  • An unsupported version of the provider is being used. 
  • Find out if your storage array has a SMI-S provider built into the array itself (some more recent storage arrays can detect this) or if the SMI-S provider is installed as a third party service on a server somewhere. For EMC, for example, it commonly uses a service called ECOM. Make sure ECOM is turned on and the service has not died. Sometimes a common issue is that the ECOM service can start and then stop right away. Make sure the ECOM service starts and stays running.
  • Licensing can also cause this behavior. Check to ensure your license is large enough to accommodate another discovery. If necessary you can try unseating your license and reseating it to make sure the SolarWinds Platform module is calculating your License correctly and allows you to add an array.