Network Management
Stop the UDT log file
This article provides steps to turn off UDT logging. By default UDT stores log files to the C:\Temp directory. This could cause issues with disk space on the drive.
First published date
Last published date
Overview
Product section
Resolution
- Stop all the Orion services. - Start and stop Orion services .
- Open Windows Explorer and navigate to directory C:\Program Files (x86)\SolarWinds\Orion\UDT\
- Create a backup of the SolarWinds.UDT.BusinessLayer.dll.config file.
- Using a text editor, open SolarWinds.UDT.BusinessLayer.dll.config
- Search for the following line:
<source name="System.ServiceModel" switchValue="Off,ActivityTracing" propagateActivity="true">
and replace it with:<source name="System.ServiceModel" switchValue="Off">
- Save the file.
- Restart all the Orion services.