Network Management

SNMPv2-MIB:authenticationFailure Trap for VLAN or Topology polling

SNMPv2-MIB:authenticationFailure Trap for VLAN/Topology polling. Solarwinds normal Topology polling will poll all Layer 2 vlan information regardless if it is shutdown.

First published date

11/29/2018 10:28 PM

Last published date

11/26/2021 10:08 AM

Overview

This article explains the possibility to view Traps for VLAN or topology polling.

Product section

Network Performance Monitor

Resolution


The following trap proceeds if you have VLANs shutdown but still show up in the vmmembership table. For example,

SolarWinds normal Topology polling polls all Layer 2 VLAN information regardless if it is shutdown. Refer to What object IDs (OIDs) does the Orion Platform poll for network topology information.

cExtSnmpTargetAuthInetAddr = "SolarWinds Poller IP ADDRESS"

cExtSnmpTargetAuthInetType = 1

authAddr = "SolarWinds Poller IP ADDRESS"

snmpTrapOID = SNMPv2-MIB:authenticationFailure

sysUpTime = 71 days 21 hours 25 minutes 50.85 second

The only current known workaround is to filter Traps or shut off these failure Traps from being sent from the device.