Process Monitor: WMI reports incorrect Memory used by Process
When viewing the details page for a Process Monitor - WMI Component, it reports incorrect values for the following: Physical Memory Used Note: The Real-Time Process Explorer feature provides accurate values for Physical Memory for the same process(es) being monitored. SAM.
First published date
Last published date
Overview
When viewing the details page for a Process Monitor - WMI Component, it reports incorrect values for the following:
Physical Memory Used
Note: The Real-Time Process Explorer feature provides accurate values for Physical Memory for the same process(es) being monitored.
Product section
Cause
This occurs when the values are too big for 32-bit counters.
Resolution
Change the platform of the application that contains the Process Monitor - WMI monitor from x86 to x64:
- Go to Settings > All Settings.
- Click SAM Settings > Manage Application Monitors.
- Select the application in question and click Edit Properties.
- Go to the Advanced section.
- Click OVERRIDE TEMPLATE next to Platform to run polling job on.
- Set the Platform to run polling job on: to x64.
- Click Submit.