Network Management

OIDs are not displayed in the UnDP MIB browser or the SolarWinds Web Console MIB browser

This article goes over what to look for and how to fix the issue when you are unable to access the MIB browser in the UnDP or the Web Console MIB browser.

First published date

7/8/2019 6:28 PM

Last published date

6/4/2025 10:54 PM

Overview

In the SolarWinds Universal Device Poller, you might see an error stating "Object reference not set to an instance of an object." when selecting the Browse MIB Tree option:



Other possible errors may be found in the UniversalDevicePoller log in C:\ProgramData\SolarWinds\Logs\Orion\NPM:

ERROR CustomePollerManagerController - GettingIcons - Unspecified error System.ServiceModel.FaultException'1[System.ServiceMOdel.ExceptionDetail]: Unspecified error (Fault Detail is equal to An ExceptionDetail, likely created by IncludeExceptionDetailInFaults=true, whose value is: System.Data.OleDb.OleDbException: Unspecified error

ERROR Program Main Form Unhandled exception. System.NullReferenceException: Object reference not set to an instance of an object. at CustomPollerManager.TreeController.InitMibParentNodes at CustomPollerManager.BrowseMIBForm.InitMibParentNodes





 

Product section

Orion Platform

Cause

  • Access to "C:\Program Data\SolarWinds\MIBs.cfg" is denied or cannot read, due to a Group Policy or Antivirus software 
    • Beginning in 2025.2, the file is "C:\Program Data\SolarWinds\MIBs.db"
  • MIB Database is corrupt, or not accessible 

Resolution

  1. Connect to the Orion Server with a Local Server Administrator account and NOT a domain account and run the Orion Permission Checker tool 
    • Even Domain Admin accounts are subject to Group Policies. If you are unable to use a local administrator account due to policies in your environment, then you may consider creating a shortcut to the Orion Permission Checker on the desktop and running it each time you log on to the server with your domain account. 
  2. Update the MIB Database