Applications Systems
Module Engine crashes due to Unhandled Exception caught in DPI Service Engine startup. Agent Messaging System initalization failed after retries: 25
This article describes the issue when the Module Engine crashes and you receive this error: Unhandled Exception caught in DPI Service Engine startup. Agent Messaging System initialization failed after retries: 25
First published date
Last published date
Overview
This article describes the issue when the Module Engine crashes and you receive this error:
Unhandled Exception caught in DPI Service Engine startup. Agent Messaging System initialization failed after retries: 25
The DPI.Businesslayer.log (C:\ProgramData\Application Data\Solarwinds\Logs\DPI\) also sends out this error message:
2015-12-31 15:34:06,483 [7] INFO SolarWinds.DPI.BusinessLayer.DPIBusinessLayerPlugin - Agent Messaging System initalization failed, retries: 4
System.ServiceModel.EndpointNotFoundException: There was no endpoint listening at net.pipe://localhost/SolarWinds/AgentManagement/Messaging that could accept the message. This is often caused by an incorrect address or SOAP action. See InnerException, if present, for more details. ---> System.IO.PipeException: The pipe endpoint 'net.pipe://localhost/SolarWinds/AgentManagement/Messaging' could not be found on your local machine.
--- End of inner exception stack trace ---
AgentManagement.AMSProxy.log (C:\ProgramData\Application Data\Solarwinds\Logs\AgentManagement\) displays this error:
2015-12-31 15:32:56,656 [6] ERROR SolarWindsAMSProxy.Communications - MessageCollection::GetMessages() - Exception [System.OutOfMemoryException: Exception of type 'System.OutOfMemoryException' was thrown.
at System.String.CtorCharPtr(Char* ptr)
at Message2MessageCLI(Message* msg)
at SolarWindsAMSPersistenceCLI.MessageCollection.GetMessages(MessageDirection md)]
Product section
Cause
Resolution
-
Check C:\ProgramData\SolarWinds\AgentManagement\Data\Store.dat if it continues to crash at 1,5GB of space.
-
Move the file to your desktop or rename it.
-
Restart the Orion services.