Tools
Kiwi Syslog Server service startup failure in versions 9.3.3 and 9.3.4
When attempting to start the Kiwi Syslog Server (KSS) service, one of the following error messages displays: Error 1053: The service did not respond to the start or control request in a timely fashion. Error 7000: The Kiwi Syslog Server failed to start due to the following error: The service did not respond to the start or control request in a timely fashion. Error 7009: Timeout (30000 milliseconds) waiting for the Kiwi Syslog Server service to connect.
First published date
Last published date
Overview
When attempting to start the Kiwi Syslog Server (KSS) service, one of the following error messages displays:
- Error 1053: The service did not respond to the start or control request in a timely fashion.
- Error 7000: The Kiwi Syslog Server failed to start due to the following error: The service did not respond to the start or control request in a timely fashion.
- Error 7009: Timeout (30000 milliseconds) waiting for the Kiwi Syslog Server service to connect.
- Component 'ipdaems81.ocx' or one of its dependencies not correctly registered: a file is missing or invalid
Product section
Cause
Resolution
- Go to C:\Windows\Microsft.NET\Framework\v.2.0.50727\CONFIG\
- Open the Machine.config file in a text editor.
- Replace <runtime/> with the following:
<runtime> <generatePublisherEvidence enable="false"/> </runtime>
- Reboot the Host Server.