Network Management
ICMP Node can be pinged but node showing down in the SolarWinds Platform when the ping packet is shortened
This article describes how to resolve an issue that occurs after adding a node using ICMP in the SolarWinds Platform.
First published date
Last published date
Overview
When you add a node using ICMP, it adds successfully. After one minute, the status goes to Warning and then Node Down while the node is still able to be pinged from the server.
By default, SolarWinds utilizes a 23-byte ping packet which is shorter than many devices expect. Below are steps for increasing the length of the ping message to 32-bytes.
Product section
Cause
Resolution
- Log in to the SolarWinds Platform Web Console.
- Click Settings > All Settings.
- Under Thresholds & Polling, click Polling Settings.
- Scroll down to Network and locate ICMP Data.
-
In the corresponding field, change "SolarWinds Status Query" to "SolarWinds Status Query xxxxxxxx"
where "x" is any character. This adds up to 32 characters, including spaces. - Click submit.
- Perform a "poll now" on the node on Node Details to see if it comes back as up.
If, after the steps above, some nodes stopped responding, you can use the following text in the ICMP data, as it is the default Windows ping:
abcdefghijklmn opqrstuvwabcdefg hi