Network Management
Hardware health Undefined for SNMP polled devices
This article provides information about the cause of a hardware health monitoring undefined error.
First published date
Last published date
Overview
Product section
Cause
Resolution
The topology polling interval is usually somewhere around 30 minutes, so if the situation more happens in this interval it is hot candidate.
Are you polling that device using SNMP v2 or v3? If you are using this, try changing it to SNMP v1 and see if the issue goes away after that. One of the changes in the new versions of NPM is that we use SNMP v1 when polling a node.
There are a few cases where some devices do not like SNMP getting bulk requests and will fail to respond; hence the intermittent unknown hardware status.
To correct this, set the device to SNMP v1 and from NPM > edit the Node Properties > use SNMP v1 which in turn will poll using SNMP to get requests. Make sure to give it some time to poll after making the change.
Creating too many custom thresholds for Hardware Health sensors can cause polling to stop or timeout.