NTA version 4.4 and later versions all require SQL for the database. FastBit database from older NTA version can no longer be used.
First published date
Last published date
Overview
Product section
Cause
Resolution
- NTA 4.4 requires MS SQL Server 2016 SP1 Standard or Enterprise edition for the Flow Storage Database.
- NTA 4.2.3 and earlier uses the FastBit database engine as a Flow Storage Database.
- It is not possible to migrate flow data from FastBit database from NTA 4.2.3 and below, to the SQL database that will be created when you upgrade to NTA 4.4 and later.
- However, data are not removed from FastBit database, it is still in the FlowStorage where it is saved. You can back up your data, but you cannot access them through NTA.
- Although you will not have access to pre-NTA 4.2.3 data via the Orion Web Console, you can restore the backup elsewhere and continue using the current version but in evaluation or another paid license.
- Non-flow data, such as applications or IP groups, will be preserved