F5 Devices hardware health details show undefined
This article describes the supported hardware health OIDs for F5 devices.
First published date
Last published date
Overview
Product section
Cause
This issue occurs because OID is possibly not supported by the F5 device.
Resolution
- Log in to the Orion server.
- Open C:\Program Files (x86)\SolarWinds\Orion and run SNMPWalk.exe.
- Enter IP address of Node and Community String.
- Click Scan and then save the resulting text file.
Hardware Health is discovered in F5 devices when the OID below is discovered:
1.3.6.1.4.1.3375.2.1.3
However, the device needs to report the OID's below which are related to the following sensors:
|
Fan |
Cpu fan |
value = 1.3.6.1.4.1.3375.2.1.3.1.2.1.3 |
|
Fan |
sysChassisFanTable (table) |
1.3.6.1.4.1.3375.2.1.3.2.1.2 |
|
PowerSupply |
Power supply status |
1.3.6.1.4.1.3375.2.1.3.2.2.2.1.2 |
|
Temperature |
Cpu temperature |
value = 1.3.6.1.4.1.3375.2.1.3.1.2.1.2 |
|
Temperature |
Chassis temperature |
value = 1.3.6.1.4.1.3375.2.1.3.2.3.2.1.2 |
To know more, attach the SNMP walk logs of the working F5 device and the non-working F5 device and submit a case to Technical Support.
Disclaimer: Please note, any content posted herein is provided as a suggestion or recommendation to you for your internal use. This is not part of the SolarWinds software or documentation that you purchased from SolarWinds, and the information set forth herein may come from third parties. Your organization should internally review and assess to what extent, if any, such custom scripts or recommendations will be incorporated into your environment. You elect to use third-party content at your own risk, and you will be solely responsible for the incorporation of the same if any.