Configuration Wizard Failed: Connection to Businesslayer service did not succeed.
This article covers where the configuration wizard shows an error that businesslayer service connection did not succeed due to timezone problem.
First published date
Last published date
Overview
The following error occurs:
Website configuration failed: Connection to the SolarWinds BusinessLayer Service did not succeed. Last error: There was no endpoint listening at net.tcp://hostname:17777/orion/core/businesslayer that could accept the message. This is often caused by an incorrect address or SOAP action. See InnerException, if present, for more details.
Sample Image:
-OR-
Website configuration failed: Connection to the SolarWinds BusinessLayer Service did not succeed. Last error: Exception of type 'SolarWinds.ApiProxyFactory.TransientApiProxyException' was thrown.
Sample Image:
Product section
Cause
Cause 1: During the Configuration Wizard made a call to the Primary Polling Engine Business Layer while the Module Engine on the Primary Poller was in a Stopped State
Cause 2: The Additional Polling Engine and the Main Polling Engine timezone are not in sync
Cause 3: Main Polling Engine and SQL Server timezone are not in sync
Resolution
Resolution 1:
a. Log into the Solarwinds Server.
b. Open Orion Service Manager.
c. Click Start Everything.
3. If the service is started them verify the times on both servers match.
Resolution 2:
- Make sure the Additional Polling Engine timezone matches with the Main Polling Engine; if not make the change then rerun the Configuration Wizard on the APE.
Resolution 3:
- Make sure Main Polling Engine and SQL Server timezone are the same; if not make the change then rerun the Configuration Wizard on the MPE.