Security Compliance

Change the CMC password

This article describes how to change the CMC password needed to log in to the SEM CMC command-line interface.

First published date

10/8/2018 8:16 PM

Last published date

5/28/2019 8:49 PM

Overview

This article details how to change the password needed to log in to the Security Event Manager (formerly Log & Event Manager) CMC command-line interface. 

Product section

Security Event Manager

Resolution

Prerequisite: You must know your current CMC password. If you no longer have the CMC password needed to log in to the CMC interface, contact SolarWinds Support who can help you reset the password. 
 

  1. Log in to the cmc command-line interface using either a hypervisor console or an SSH client via port 22 or 32022 (if LEM is 6.2.1 or earlier, only port 32022 is open).
  2. Type appliance, and then press Enter.
  3. Type password, and then press Enter.
  4. Complete the wizard to change the password.
  5. To return to the root CMC command line, type exit, and then press Enter.
  6. To log out and close the CMC interface, type exit, and then press Enter again.