Network Management
Blue Coat Invalid data received from remote server in NCM
When you attempt to add the BlueCoat node in NCM you receive Test Failed Connection refused. Invalid data received from remote server. Protocol error.
First published date
Last published date
Overview
Product section
Cause
- SSH2
NCM tries to negotiate an AES algorithm first (any type). If that fails, NCM tries TripleDES. If TripleDES is not available, NCM tries Blowfish. If Blowfish fails, NCM drops the connection instead of trying DES, which most (new) servers don't support because of its poor security.
For more Details please see the KB post below.
NCM supported encryption protocols for SSH
If the device has CSCipher = aes128-cbc, when NCM sees the Cipher it tries to get the connection using AES. The device refuses the connection because the device is not configured to use this AES cipher and the connection is refused.
Resolution
This is known issue. SolarWinds suggests trying the following workarounds:
- Configure device and deny usage of any other ciphers except AES-256 on device side.
- Use the SSH Auto
- Enable Telnet and download the device configuration