Observability
Additional polling engine installer fails to connect to the primary SolarWinds Platform server over port 17777
Installing or upgrading an Additional Polling Engine fails due to connection issues.
First published date
Last published date
Overview
When installing an additional polling engine (APE) on a temporary server, the installer fails to complete because it cannot successfully communicate with the primary SolarWinds server over TCP port 17777, even though basic connectivity (ping) works and an existing additional poller is already functioning in the environment.
Product section
Cause
A configuration issue on the primary SolarWinds polling engine prevented stable communication over TCP port 17777 (SolarWinds Information Service / Administration Service) required by the additional polling engine installer.
After confirming that:
- The installer was targeting the main SolarWinds application server (this-sw) and not the SQL server (this-swsql), and
- Firewall rules allowed communication,
Running the SolarWinds Configuration Wizard (repair) for Database and Website/Services on the primary polling engine repaired the platform configuration and bindings. The additional polling engine installation then completed successfully.
Resolution
Resolution:
- Confirm the installer targets the correct server
- In the additional polling engine installer, enter the hostname/FQDN of the main SolarWinds application server (main polling engine), not the SQL server, unless they are the same machine.
- Verify connectivity to port 17777 from the APE server
- From the additional poller server, use a connectivity test tool such as
Test-NetConnectionto confirm TCP port 17777 is reachable on the primary SolarWinds server. - If the test fails, review Windows Firewall and any AV/EDR rules on both servers and ensure there is an allow rule for TCP 17777 between the APE and the primary server.
- From the additional poller server, use a connectivity test tool such as
- Repair the SolarWinds Platform configuration on the primary polling engine
- If the installer is pointing to the correct server and network/firewall checks succeed but installation still fails, run the SolarWinds Configuration Wizard on the primary SolarWinds server.
- Select Database and Website/Services only, complete the wizard to repair the configuration and service bindings, verify that port 17777 is listening, and then rerun the additional polling engine installer; the installation should now complete successfully.
Related Articles:
SolarWinds Port Requirements
Ports for additional poller to communicate with APM – THWACK