Issue

PRI trunk polling data appears to be missing on some devices using IOS 15.X, such as Cisco 2921 series.

Cause

Different output of CLI commands.

Resolution

Update the appSettings section of the SolarWinds.Orion.IpSla.Pollers.dll.config configuration file:

  1. Stop SolarWinds services:
    Open the Orion Service Manager tool in the SolarWinds Orion folder (SolarWinds Orion > Advanced Features > Orion Service Manager) and click Shutdown Everything.
  2. Go to the VoIP Monitor folder in your Program Files (C:\Program Files (x86)\SolarWinds\Orion\VoIP Monitor) and open the SolarWinds.Orion.IpSla.Pollers.dll.config file.
  3. Replace the appSettings section in the configuration file with the code in the attached document (app_settings.txt).
  4. Save your changes to the configuration file.
  5. Restart the services:
    Click Start Everything in the Orion Service Manager.

 