Overview

This article describes the issues with VNQM performance as well as the following error message that shows up in the Data processor logs:

2016-03-09 08:56:44,481 [STP DatabaseProcessing Thread #1568] ERROR SolarWinds.Orion.IpSla.Collector.DAL.CCM.ResultHandler - ccmGateway Table. [Index=449]
System.Data.SqlClient.SqlException (0x80131904): String or binary data would be truncated.

Environment

VNQM version 4.2.x

Cause 

The error is caused by issues with the actual Gateways being monitored in VNQM.

Resolution

  • Check the Gateways by going to Settings > VNQM > Manage Gateways.
  • Check the credentials and make sure none of them are failing for CLI.
  • Verify that VNQM is loaded on all the pollers.

 