The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Virtualization Manager (VMAN) > VMAN and Orion integration: Data Sources are out of sync

VMAN and Orion integration: Data Sources are out of sync

Created by Miroslav Beno, last modified by MindTouch on Jun 23, 2016

Views: 229 Votes: 0 Revisions: 3

Overview

The NPM Web Console shows that Data Sources monitored by VMAN and Orion are out of sync.

Environment

VMAN intergrated with NPM

Resolution

On the Orion Web Console, click Settings > Virtualization Settings > Run Synchronization Wizard.

If the issue is not resolved, perform the following:

Note: Verify that VMAN and NPM are on the latest versions.

  1. On the Orion Web Console, click Settings > Virtualization Settings > Setup Virtualization Manager Integration.
  2. Click Disable integration and wait for one cycle to complete, which takes approximately 15 minutes.
  3. Re-integrate VMAN with NPM.

 

 