Our new eBook will teach you the fundamentals and help you create monitors and alerts that are effective, meaningful, and actionable. Monitoring is more than a checkbox on your to-do list. This free eBook will give you practical advice to help you succeed in all aspects of monitoring – discovery, alerting, remediation, and troubleshooting. Don’t miss out on this indispensable resource for newbies, experienced IT pros, and everyone in between. Register Now.

Home > Success Center > Virtualization Manager (VMAN) > Manage Alerts page is empty after upgrade

Manage Alerts page is empty after upgrade

Updated March 14, 2017

Overview

Unable to view the Manage Alerts page in the Orion Web Console or the page just returns as empty after upgrading VMan to v7.0. 

 

The logs are showing the following errors:

2016-11-03 08:59:37,918 [154] (1460) ERROR NewAlertingService - (null)  Failed to retrieve alerts.
System.InvalidCastException: Cannot cast DBNull.Value to type 'System.Int32'. Please use a nullable type.
at System.Data.DataRowExtensions.UnboxT`1.ValueField(Object value)

Environment

Orion VIM 7.0

Cause 

There are action assignments for non existing actions.

Resolution

Take a full backup of your Orion database, and then run following query

DELETE FROM ActionsAssignments WHERE ActionID NOT IN (SELECT ActionID FROM Actions);

This will delete obsolete action assignments.

Try opening Manage Alerts page after that.

 