Patch Manager is an intuitive patch management software which extends the capabilities of WSUS and SCCM to not only patch Windows® servers and workstations, and Microsoft® applications, but also other 3rd-party applications which are commonly exploited by hackers. Learn more about our patch management solution.

 

Home > Success Center > User Device Tracker (UDT) > The Controls collection cannot be modified because the control contains code blocks in UDT 3.2.2

The Controls collection cannot be modified because the control contains code blocks in UDT 3.2.2

Created by Justin Wyllys, last modified by MindTouch on Jun 23, 2016

Views: 69 Votes: 0 Revisions: 14

Overview

The node details page is not loading for some users and the following error appears:

The Controls collection cannot be modified because the control contains code blocks (i.e. <% ... %>)

2015-07-01 10_33_55-.png

Environment

UDT version 3.2.2

Cause

This may occur when the Port Details resource is included in the Node Details.

Resolution

A)

  1. Go to Settings > Manage Views.
  2. Select Node Details - Summary.
  3. Click Edit.
  4. Select Port Details.
  5. Click Delete.
  6. Click Save.

 

B)

-Navigate to C:\Program Files (x86)\SolarWinds\Orion\UDT\

-Verify that Solarwinds.UDT.BusinessLayer.dll (UDT 3.2.2 Hotfix-2 is not Blocked and Unblock it if so

Last modified
04:03, 23 Jun 2016

Tags

Classifications