Submit a ticketCall us

Announcing NPM 12.2
With NPM 12.2 you can monitor your Cisco ASA firewalls, to monitor VPN tunnels for basic visibility and troubleshooting tunnels. NPM 12.2 also uses the SolarWinds Orion Installer so you can easily install and upgrade one or more Orion Platform products simultaneously.
See new features and improvements.

Home > Success Center > User Device Tracker (UDT) > The Controls collection cannot be modified because the control contains code blocks in UDT 3.2.2

The Controls collection cannot be modified because the control contains code blocks in UDT 3.2.2

Created by Justin Wyllys, last modified by MindTouch on Jun 23, 2016

Views: 179 Votes: 0 Revisions: 14

Overview

The node details page is not loading for some users and the following error appears:

The Controls collection cannot be modified because the control contains code blocks (i.e. <% ... %>)

2015-07-01 10_33_55-.png

Environment

UDT version 3.2.2

Cause

This may occur when the Port Details resource is included in the Node Details.

Resolution

A)

  1. Go to Settings > Manage Views.
  2. Select Node Details - Summary.
  3. Click Edit.
  4. Select Port Details.
  5. Click Delete.
  6. Click Save.

 

B)

-Navigate to C:\Program Files (x86)\SolarWinds\Orion\UDT\

-Verify that Solarwinds.UDT.BusinessLayer.dll (UDT 3.2.2 Hotfix-2 is not Blocked and Unblock it if so