Submit a ticketCall us

Looking to compare latest NPM features with previous versions of NPM?
The NPM new feature summary offers a comparison of new features and improvements offered with this release.

 

Home > Success Center > User Device Tracker (UDT) > Stop the UDT log file

Stop the UDT log file

Table of contents
Created by Interspire Import, last modified by MindTouch on Jun 23, 2016

Views: 131 Votes: 4 Revisions: 9

Overview

This article provides steps to turn off UDT logging. By default UDT stores log files to the C:\Temp directory. This could cause issues with disk space on the drive.

Environment

All UDT versions

Steps

  1. Stop all the Orion services. - How to Start/Stop Orion Services
  2. Open Windows Explorer and navigate to the following directory:
    C:\Program Files (x86)\SolarWinds\Orion\UDT\
  3. Create a backup of the SolarWinds.UDT.BusinessLayer.dll.config file. 
  4. Using a text editor, open SolarWinds.UDT.BusinessLayer.dll.config.
  5. Search for the following line:
    1. <source name="System.ServiceModel" switchValue="Off,ActivityTracing" propagateActivity="true">
    2. Change it to: <source name="System.ServiceModel" switchValue="Off">
  6. Save the changes.
  7. Start all the Orion services. - How to Start/Stop Orion Services.
Last modified
04:03, 23 Jun 2016

Tags

Classifications