Submit a ticketCall us

Putting Your Logs Where They Belong with the New SolarWinds Log Manager for Orion

The new SolarWinds® Log Manager for Orion® finally puts your log data right where it belongs, in the heart of your Orion console. Gain insight into the performance of your infrastructure by monitoring your logs in a unified console allowing you to see a wealth of information about the health and performance of your network and servers.

Reserve a Seat for Wednesday May 23rd 11am CDT | Reserve a Seat for Tuesday May 22nd 10:30am GMT | Reserve a Seat for Tuesday May 22nd 1pm SGT / 3pm AEST

Home > Success Center > User Device Tracker (UDT) > Shut down port on UDT fails

Shut down port on UDT fails

Updated March 23, 2017

Overview

This article provides brief information and steps to resolve the following error in the Device Tracker Port Details View:

UDT setting Administrative Shutdown 1121 fails for portids 1121.

Environment

All UDT versions

Cause 

A node was added in Orion using an SNMP Community String that does not have Write access to the device (having Read Only access).

Below shows an example running configuration on a switch:

 

The community string used is public which is a Read Only access:

Resolution

Use a Community String that has Read/Write access when adding the node in Orion.

 

Last modified

Tags

Classifications

Public