Having a unified ticketing and asset management system for all the departments in your company can provide end-users with a seamless experience and make things easier for your IT team. Yet, with different business tasks and objectives, many departments don’t fully understand the capabilities of Web Help Desk and how the software can be customized for effective use in their departments.
Register Now.

Home > Success Center > User Device Tracker (UDT) > Shut down port on UDT fails

Shut down port on UDT fails

Updated March 23, 2017

Overview

This article provides brief information and steps to resolve the following error in the Device Tracker Port Details View:

UDT setting Administrative Shutdown 1121 fails for portids 1121.

Environment

All UDT versions

Cause 

A node was added in Orion using an SNMP Community String that does not have Write access to the device (having Read Only access).

Below shows an example running configuration on a switch:

 

The community string used is public which is a Read Only access:

Resolution

Use a Community String that has Read/Write access when adding the node in Orion.

 