Virtualization can give you enormous flexibility with future workloads and can be a key enabler for other areas, like cloud computing and disaster recovery. So, how can you get a handle on the performance challenges in your virtual environment and manage deployments without erasing the potential upside? Learn the four key areas you need to be focusing on to help deliver a healthy and well-performing data center.

Get your free white paper.

Home > Success Center > User Device Tracker (UDT) > UDT - Knowledgebase Articles > There was no response from the UDT Service Engine located at "Server: 'XXXX' Port: '17777' EngineID: 'X'"

There was no response from the UDT Service Engine located at "Server: 'XXXX' Port: '17777' EngineID: 'X'"

Created by Eric Bryant, last modified by MindTouch on Jun 23, 2016

Views: 1,185 Votes: 0 Revisions: 5

Overview

The following error is received in UDT:

 

There was no response from the UDT Service Engine located at "Server: 'XXXX' Port: '17777' EngineID: 'X'"

Environment

UDT 3.2.2 HotFix 2 or any HotFix that replaces the Solarwinds.UDT.BusinessLayer.dll file.

Cause 

When the dll is downloaded from a browser and then replaced in Windows Explorer through copy and paste, the dll becomes blocked.

Resolution

  1. Navigate to Program Files (x86)\SolarWinds\Orion\UDT\SolarWinds.UDT.BusinessLayer.dll.
  2. Right-click the Solarwinds.UDT.BusinessLayer.dll file and select Properties.
  3. Open the Security option in the General tab. If you see a message that the file might be blocked, click the Unblock button.
  4. Restart the Orion services using the Orion Service Manager.