Get valuable help when it comes to tracking and monitoring changes. SolarWinds® Server Configuration Monitor (SCM) is designed to help you: detect, track, and receive alerts when changes occur, correlate system performance against configuration changes, compare server and application configuration against custom baselines, and verify application and system changes.

Learn more.

Home > Success Center > User Device Tracker (UDT) > UDT - Knowledgebase Articles > The Controls collection cannot be modified because the control contains code blocks in UDT 3.2.3

The Controls collection cannot be modified because the control contains code blocks in UDT 3.2.3

Created by Con Finucane, last modified by Malik Haider on Sep 23, 2017

Views: 1,037 Votes: 2 Revisions: 5

Overview

When logging in to the Orion Console and access the Nodes Detail page, you get the error:

 

Error:<The Controls collection cannot be modified because the control contains code blocks (i.e. <% ... %>)>

2015-07-01 10_33_55-.png

 

NPM 12.x

image.png

Environment

UDT 3.2.3

Cause

This may occur when the Port Details resource is included in the Node Details and is not loading properly.

Resolution

  1. Go to Settings > Manage Views.
  2. Select Node Details - Summary.
  3. Click Edit.
  4. Select Port Details.
  5. Click Delete.
  6. Click Save.
  7. Go to Settings > Manage Views.
  8. Select Node Details - Summary.
  9. Click Edit.
  10. Select the green +.
  11. Search for port detail and re-add back to the page.
  12. Check if the page can now load correctly.

If the page does not load you need to rebuild the Orion website.

 