Overview

This article describes how to turn off UDT logging. By default UDT stores log files to the C:\Temp directory. This could cause issues with disk space on the drive.

Environment

All UDT versions

Steps

  1. Stop all the Orion services. - How to Start/Stop Orion Services
  2. Open Windows Explorer and navigate to the following directory:
    C:\Program Files (x86)\SolarWinds\Orion\UDT\
  3. Create a backup of the SolarWinds.UDT.BusinessLayer.dll.config file.
  4. Using a text editor, open SolarWinds.UDT.BusinessLayer.dll.config
  5. Search for the following line:

    <source name="System.ServiceModel" switchValue="Off,ActivityTracing" propagateActivity="true">

    and replace it with:

    <source name="System.ServiceModel" switchValue="Off">

  6. Save the file.
  7. Restart all the Orion services.