Join us on Wednesday, November 29, 2017 at 11 a.m. CT, as we discuss the benefits of effectively integrating your help desk software with remote support solutions to help increase the efficiency of IT administration, improve communication, and decrease mean time to resolution (MTTR) for IT issues of all sizes. This directly impacts end-user satisfaction and your business’ bottom line. Register Now.

Home > Success Center > User Device Tracker (UDT) > Interface Down Events when end device disconnects

Interface Down Events when end device disconnects

Created by Brian O'Donovan, last modified by MindTouch on Jun 23, 2016

Views: 98 Votes: 1 Revisions: 5

Overview

Receiving many "Interface Down" Events due to devices being disconnected from access ports/interfaces.

Environment

All UDT versions when installed with NPM​

Cause 

This due to monitoring all the access ports in NPM and UDT. When an end device is disconnected from the port/interface, the port/interface goes down. If the port/interface is monitored by NPM, an "Interface Down" event will be triggered

Resolution

Do not monitor access ports/interfaces in NPM. Only monitor them in UDT.