The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Storage Resource Monitor (SRM) > Storage Resource Monitor 6.5 Release Notes

Storage Resource Monitor 6.5 Release Notes

 

Created by Nigel, last modified by Nigel on Sep 13, 2017

Views: 368 Votes: 0 Revisions: 24

Last updated: September 13, 2017

These release notes describe the new features, improvements, and fixed issues in this release. They also provide information about upgrades and describe workarounds to known issues.

New features and improvements

Read this section for descriptions of the new features and improvements SRM offers in this release, and compare this release with previous releases of SRM.

Support for new arrays

SRM now supports the addition array types:

  • EMC VMAX Flash Family
  • IBM FlashSystem A9000/A9000R
  • IBM DS 8xxx
  • NetApp EF
  • NetApp AFF

For a complete list of arrays supported by SRM 6.5, click here

Additional hardware health monitoring

Hardware health monitoring has been added for the following array types:

  • EMC VMAX
  • EMC VNX CLARiiON
  • EMC VNX Celerra/VNX Gateway
  • IBM SVC/V7000/V3700

For a complete list of  arrays that support hardware health monitoring, and the sensors supported, click here.

Other improvements

  • TLS support.
  • Includes all 6.4 hotfixes.

SRM now uses Orion Platform 2017.3

This provides the following new features and improvements that can be used with SRM:

Installer

Use the SolarWinds Orion Installer to install and upgrade one or more Orion Platform products simultaneously in your environment. When installing new products into an existing Orion environment, the Orion Installer verifies compatibility between the product versions and notifies you if additional steps are needed. The Orion Installer also supports upgrades from older versions of the software with a generated upgrade path, merging the capabilities of the Product Upgrade Advisor into the installer.

  • .NET 4.6 is required to use the new installer and will be downloaded when you run the installer. Do not stop the installation after installing .NET 4.6 due to compatibility issues with older versions of SolarWinds software. A reboot may be required after installing .NET.
  • To eliminate compatibility issues, all required Orion Platform products are upgraded when you complete the Orion Installer. 

The installer:

  • Installs or upgrades all products from a single screen. You do not need to download files for each product.
  • Provides an easy-to-follow install path when required. If you upgrade from an older product version, the installer provides upgrade paths custom-made for your current environment so you can complete complex upgrades and installations with ease.
  • Runs preflight checks to ensure your environment specifications match the system requirements for selected product installs. If changes are needed, the installer provides guidance for required versions.
  • Automatically starts the Configuration Wizard as needed after product installs to complete database and configuration tasks.

» Read more about the Orion Installer

Dashboards and widgets

The new Customize Page significantly simplifies and streamlines how you build your dashboards or views. Drag and drop resources, now known as widgets, exactly where you want them on your page, including on to blank areas to create new columns.

  • Start searching for widgets in two clicks from any customizable page.
  • Mark favorite widgets so you can quickly add them to new dashboards or pages.
  • Drag and drop widgets directly on to the pages or move widgets to new locations.

» Read more about dashboards

Windows Authentication for SQL

Secure the connection between your Orion server and your SQL server

Increase your security compliance by using Windows authentication for both day-to-day data storage and retrieval between your Orion server and your SQL server and during the initial setup of your database server in the Configuration Wizard. 

Do not use a Windows account with a password policy applied.

You can also enable SSL directly in the Configuration Wizard to encrypt the information exchanged between your Orion server or additional polling engines and your SQL server, independent of SSL settings on your SQL server.

SSL must be configured on your SQL server to utilize this feature.

Multi-subnet High Availability

Distribute HA pool members to different subnets in this new update to SolarWinds High Availability for near instantaneous, automated failover to a secondary server on a different subnet. Create an HA pool , update your secondary server, and activate HA in your current Orion environment just as easily as before. 

» Read more about multi-subnet High Availability (DR)

PerfStack

Get both broad and in-depth visibility into your environment by correlating disparate data points across your infrastructure, including on-premise, cloud, and hybrid environments, in easy-to-read charts.

This version of PerfStack™ includes:

  • Real-Time Polling at approximately one second intervals for selected metrics.
  • Increased the number of supported metrics and products
  • View the data behind supported charts with the Data Explorer.
  • Drag and drop entities to the chart area.
  • Open an analysis project directly from an entity with common metrics already added.
  • Go to the details page for an entity from the Performance Analysis dashboard.

» Read more about these changes

Manage Nodes

The new Manage Entities page presents information about your nodes in a more intuitive fashion, including filtering options and contextual management options.

  • Search your entities using the display name or IP address.
  • Sort entities by display name, status, or IP address.
  • Quickly view which nodes are muted and resume alerts with one click.
  • Add more information by editing the rows

» Read more about these changes

Other improvements

  • Deploy Orion agents to Raspberry Pi (Raspbian version 8.0 on ARMv6 or ARMv7 processors, 32-bit). If you upgrade to this version, you can install any Linux agent plug-ins on Rasberry Pi devices.
  • Improved memory performance.

This version changes the system requirements. .NET 4.6.2 is required and Windows Server 2008 and SQL Server 2008 are no longer supported for installations. 

New customer installation

Please refer to the SolarWinds SRM Installation Guide.

Before you upgrade! 

Use the following resources for planning and upgrading:

  • Since SRM 6.4, SRM no longer supports Windows OS 2008 and 2008 R2 and Microsoft SQL Server 2008 R2. For more information, see End of support notices. 

  • When upgrading, if you added a site binding to a host name before you upgrade, you must bind the Orion Web Console to a fully qualified domain name (FQDN). See this article.

  • When upgrading with custom menus, you cannot see the Performance Dashboard link in the menu. For details, see this article.

  • Since SRM 6.4, the Alert Manager application has been deprecated and removed. Please use the web-based Alert Manager through the Orion Web Console to create and manage alerts. For more information, see End of support notices.

  • When upgrading an Additional Poller, you may receive this error :"The license we have for Orion Scalability Engine is outdated". See this article for details to resolve.

  • If you have written your own code, such as changing SolarWinds .css files or adding .js files, it may be overwritten with the upgrade. You can learn more about custom code in this article.
  • If you have edited resource properties, the All Groups resource may be empty after upgrading.
  • When upgrading, using the group by feature for custom properties may return no results, and the data loading may hang or not complete. All regular functionality is unaffected by the issue. 
  • Always upgrade NPM first if you have it installed. NPM includes platform features to support all Orion products.
  • If you have SAM without NPM, upgrade SAM first. SAM includes platform features to support all Orion products.
  • Always use the Product Upgrade Advisor to build your upgrade path.

How to upgrade

If you are upgrading from a previous version, use the following resources for planning and implementation:

Fixed issues

SRM 6.5 fixes the following issues.

Case number Description
975411 Fixed an issue where VMAN Storage information  was not populated in the visualization tab.
1088210 Fixed an issue where an alert email was not sent due to email format error.
1043422 Fixed an issue where incorrect wrong disk capacity was displayed for Dell Compellent arrays.
1104345 Fixed an issue where Dell Compellent arrays were not being polled.
1153439 Fixed an issue where the LUN Performance Summary was not displayed.
1156097 Fixed an issue where IBM DS4xxx array passed the SMI-S provider test but was unreachable.
1056020 Fixed an issue where latency metrics were not displayed for NetApp Cluster-mode (OnTAP 8)
1137049,
1112771,
1108457,
1137043,
1147446
Fixed an issue where IBM V3700/SVC/V7000 running Firmware 7.8.x.x was stuck at "Waiting for first poll".
1123708 Fixed an issue where File Share Quota Data was not showing up in the Web Console or Database despite Poller logs showing it was retrieved from the shares.
1152511 Fixed an issue where the NetApp array was not completing the initial capacity polling.
1082534 Fixed an issue where dynamic baseline thresholds were not being shown.
1077723 Fixed an issue where incorrect data was being shown for NetApp.

Orion Platform Fixed issues

Orion Platform 2017.3 fixes the following issues.

Case number Description

1170324, 1135026, 1164963, 

1144272, 

1141633,

1151850,

1146475,

1144596,

1159800, 

1147767, 1143080, 1138560,   1137648, 1138009, 1124158, 1163713 

The global navigation menu bar is missing.

1152162

Netpath cannot access the requested path.

1136599, 1143676, 1133928, 1110258 

Netpath times out and only shows a single point in time.

24135

A CPU utilization issue on multi-core nodes running Microsoft® Windows Server® 2008 R2 when using WMI or the agent polling method.

1169799

Orion agent Debian-based Linux packages are missing a space in the version information.

1152643

Agents appear connected on the Manage Agents page, but cannot send information back to the server after an upgrade.

1081143, 1113910

Linux-based Orion agents fill the /tmp folders with TaskProperties files.

1068885

The Orion agent cannot differentiate between two nodes with the same IP address when one node is behind a NAT.

1053867

Cannot add SNMPv3 credentials to poll a Windows node with the Orion agent.

1046185

When deploying an Orion agent, the Application Event log has the following error:

The job schedule database file is corrupt....

1199142, 1103578, 1092273, 1139529 

IPv6 nodes polled with ICMP do not return correct values or are unreachable.

955013, 1024495, 1138773, 1202980 

Incorrect time zone information for the southern hemisphere and the alerts are scheduled one hour earlier than intended.

1179158

Repeated alert actions stop working after one of the following occurs:

  • restarting Alerting Service v2
  • modifying an alert action
  • losing the connection to the database or Information Service v3
1164854, 1196999, 1190898

Domain users or groups added after an upgrade cannot log in with a error:

SolarWinds.Orion.Web.OrionMixedModeAuth - (null) Failed to retrieve WindowsIdentity for user <user>: System.Security.Authentication.AuthenticationException Cannot logon '<user>' via Interactive/Default.

1082111, 1009462, 1073184, 1102489, 1116840, 1113529, 
1164723, 1195031, 1147707, 1130235, 

Repeated alert actions do not trigger when an alert is edited or the alerting service is restarted.

1187535, 1126092, 1091068, 1126361, 1160693, 1034970, 1067830, 1075247, 1067457, 1086208, 1105612, 1124335, 1138711, 1146216, 1152348, 850464, 961469, 944283, 1005146, 1004940, 1023357, 1087128, 1090237, 1082382, 1108013, 1116804, 1112982, 1119012, 1113720, 1124724, 1134211, 1145831, 1109627, 1180971, 1187535, 1154647

The Node Reboot alerts and event-based alerts do not trigger.

 

1190180, 1167620, 1174631, 1175273, 1171806, 1180712, 1181381, 989718 

Scheduling for alerts and reports is one hour off.

1183756, 1032145, 1066438, 

Some alert actions cannot be simulated and return an error similar to the following:

2017-06-22 08:01:43,724 [140] INFO  AlertingLogger - NetObjectData for entity Alerting: swis://example.com/Orion/Orion.Nodes...olumeID=#####/
ForecastCapacity/EntityType="Orion.Volumes",MetricId=3 (AlertObjectId =  ) does not exist. Alert action ###: 'Post to http://192.168.1.1:8081/http/applications_solarwinds' will not be executed.

 

1148595, 1133531, 1135332, 1138622, 1142313, 1143110, 1138788, 1150043, 1152481, 1113579, 1113898, 1138326, 1153010, 1141811, 1153896, 1157577, 1171634, 1155356, 1147223, 1143539, 1153845, 1134872, 1148761, 1154253, 1128086, 1158176, 1124099, 1060558  

The Orion Web Console is slow after an upgrade due to SWIS v3 using a large amount of memory.

1180808, 1116741 

Account limitations applied to groups intermittently display unwanted nodes.

1094832, 1130773, 1159671, 1171385, 1171682, 1166910, 1116402, 

Some resources are not listed due to HEX-string values in the OIDs.

1139372, 1154482, 1156463, 1143611, 1118211, 1174841

Saved changes to Network Atlas maps do not display when your Orion server time zone is set to any negative time zone, such as UTC-5.

1126358, 1148560, 1144414, 1152358, 1159419, 1101641, 1118741, 1120297, 1107631, 1139310, 1130725, 1150164, 1175369, 1143012, 1155599

You are prompted to log in when viewing reports. PDF reports have a screenshot of the Orion Web Console login page or an Unexpected website error.

1148059, 1165475, 1166654, 1168955, 1171034, 1139724, 1156926, 1152091, 1148399, 1147728, 1146219, 1081084, 1148739 

Performance issues due to deadlock and locking in the OrionServers table.

1018994, 1084453, 1095223, 1113681, 1163514, 1083077, 1107391, 1123401, 1110556, 1130277, 1170228, 1033563, 1069910

Custom Object resources are very slow or time out when editing or creating them.

1163156

CPU is high for trap services.

1142839

Page loading times are high.

1103629, 1163273 

Cannot import custom properties for groups to a Worldmap.

1166215, 1166270 

When integrated with ServiceNow instances with a large number of customizations, alerts do not work as expected.

1165130, 1105005 

Devices do not poll when you are missing SNMP v3 credentials.

1155215, 1155352, 1058519, 1096595, 1106405, 1089958, 1140354, 1138870, 1112997, 1132300, 

Automatic monitoring settings are reset to the default after the Configuration Wizard runs.

1066550, 1100302, 1146412, 1124954 

Cannot open the Advanced Configuration page.

1132857

When copying the default Node Details view, the Quality of Experience and Asset Inventory sub pages do not copy the appropriate resources.

1136856, 1117267, 1116460, 1106393

SNMPv3 credentials are not correctly assigned to nodes.

 

1141314

The time does not update in the Orion Web Console.

1136721

The Managed Alerts page does not completely load, and you cannot filter alerts.

1132507, 1070372, 1056500, 1121349, 979463, 897210

Alerts created with a disabled user do not work as expected, and the Active Alerts page may be blank or have an error.

1118106, 1141738, 

ServiceNow integration stops working if you mass edit incidents.

1128614

Cannot advance to the next Manage SNMPv3 credentials page.

1092013, 1097173, 1112369, 1117267, 1125348

SNMPv3 credentials can be deleted or incorrectly updated when mass editing nodes that use different polling methods.

1100922, 1122034 

Cannot create ServiceNow incidents due to missing roles.

1106587

Limitations are not applied correctly to alerts.

1083182, 1142800, 1120175, 1118112, 1120175, 1109625 

Cannot add or search for domain accounts when using LDAP.

1110844, 1119752, 1100383, 1101723, 1112970, 

ServiceNow incidents re-active.

1109266, 1072704, 1056235, 1052510, 1118865 

Volume added using WMI stop polling.

1118901, 1076841, 1097612, 1089416, 1087776, 1024125, 968951,  

Network Atlas maps load slowly or not at all. You may receive an error similar to the following:

Operation in progress, waiting for a connection...

1106647

Device type 1.3.6.1.4.1.9.1.1852 is not completely recognized

1103781, 1097218, 1108197 

Some features, such as the Real-Time Process Explorer, stop functioning on you additional polling engines with the following error:

The Job Engine password files are out of sync.

1102878, 1102634 

The Settings page is blank when the default document is disabled in IIS.

1100794, 1058790, 993082 

The ServiceNow incident resource does not display data.

1097774, 1054466

HTML reports are embedded with What's New in the UI information.

705254, 993277, 1095107, 1081919, 1031691, 973096 

When you monitor multi-core devices with WMI, the polled results are inconsistent and may return errors.

1080560

The Orion Service Manager opens with the following message:

Error starting service manager

1086858

New Cisco switches (C 2990CX) display an incorrect Machine Type.

1080095

The Custom Query resources does not page correctly.

1074893, 1044414, 1013808, 977233, 1059448, 1046813, 1027885, 940870, 1017984

Cannot open Quality of Experience resources in the Orion Web Console or Network Atlas.

 

946894, 1018470 

L3 polling data is incorrect for some nodes.

869365, 1001732

The job engine for SNMP polling become unresponsive and polling does not complete.

913105

Large spikes in the Data Transmitted metric on non-US English installations

818878

Trigger conditions affect what is displayed in the Detected Objects window.

Known issues

 

End of life 

See End of Life Policy for information about end of life and end of engineering for SolarWinds products.

Version EoL Announcements EoE Effective Dates EoL Effective Dates
6.2 September 13, 2017:
End-of-Life (EoL) announcement - Customers on Storage Resource Monitor version 6.2.x should begin transitioning to Storage Resource Monitor version 6.4 or higher.
December 13, 2017:
End-of-Engineering (EoE) - Service Releases, bug fixes, workaround, and service packs for Storage Resource Monitor version 6.3.x or older will no longer be actively supported by SolarWinds.
December 13. 2017:
End-of-Life (EoL) - SolarWinds will no longer provide technical support for Storage Resource Monitor version 6.2.x or older.
6.1 March 15, 2017:
End-of-Life (EoL) announcement - Customers on Storage Resource Monitor version 6.1.x should begin transitioning to Storage Resource Monitor version 6.4 or higher.
June 15, 2017:
End-of-Engineering (EoE) - Service Releases, bug fixes, workaround, and service packs for Storage Resource Monitor version 6.1.x or older will no longer be actively supported by SolarWinds.
June 15, 2018:
End-of-Life (EoL) - SolarWinds will no longer provide technical support for Storage Resource Monitor version 6.1.x or older.

As of this version, all versions of Failover Engine (FOE) have entered the End of Life life cycle. For more information about the End of Life cycle, see this article.

End of support

For information about supported versions of SolarWinds products, see this article.

Type Details
Microsoft SQL Server

SQL 2008 and 2008 R2 are no longer supported as your database server as of this release.

SolarWinds recommends that you upgrade directly to SQL 2016 at your earliest convenience.

Microsoft Windows Server

You cannot install SolarWinds Orion products on Windows Server 2008 R2 as of this release.

SolarWinds recommends that you upgrade to Windows Server 2012, 2012 R2, or 2016 at your earliest convenience.

Export to PDF feature

The Export to PDF button is no longer available.

SolarWinds recommends that you use the Save as PDF functionality built into your browser.

Version history 

SRM 6.4

SRM 6.3

SRM Profiler 6.2.3

SRM 6.2.1

SRM 6.2

SRM 6.1.1

SRM 6.1

 

Legal notices

© 2017 SolarWinds Worldwide, LLC. All rights reserved.

This document may not be reproduced by any means nor modified, decompiled, disassembled, published or distributed, in whole or in part, or translated to any electronic medium or other means without the prior written consent of SolarWinds. All right, title, and interest in and to the software and documentation are and shall remain the exclusive property of SolarWinds and its respective licensors.

SOLARWINDS DISCLAIMS ALL WARRANTIES, CONDITIONS OR OTHER TERMS, EXPRESS OR IMPLIED, STATUTORY OR OTHERWISE, ON SOFTWARE AND DOCUMENTATION FURNISHED HEREUNDER INCLUDING WITHOUT LIMITATION THE WARRANTIES OF DESIGN, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND NONINFRINGEMENT. IN NO EVENT SHALL SOLARWINDS, ITS SUPPLIERS, NOR ITS LICENSORS BE LIABLE FOR ANY DAMAGES, WHETHER ARISING IN TORT, CONTRACT OR ANY OTHER LEGAL THEORY EVEN IF SOLARWINDS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

The SolarWinds and other SolarWinds marks, identified on the SolarWinds website, as updated from SolarWinds from time to time and incorporated herein, are registered with the U.S. Patent and Trademark Office and may be registered or pending registration in other countries. All other SolarWinds trademarks may be common law marks or registered or pending registration in the United States or in other countries. All other trademarks or registered trademarks contained and/or mentioned herein are used for identification purposes only and may be trademarks or registered trademarks of their respective companies.

Last modified

Tags

Classifications

Public