Submit a ticketCall us

Training ClassThe Orion® Platform Instructor-led Classes

Provided by SolarWinds® Academy, these trainings will introduce users to the Orion Platform and its features, management, and navigation. These courses are suitable for users looking to discover new tips, tricks, and ways to adapt their Orion products to better suit their monitoring needs:
Deploying the Orion Platform
Configuring Orion views, maps, and accounts
Configuring Orion alerts and reports

Reserve your seat.

Home > Success Center > Storage Resource Monitor (SRM) > SRM - Knowledgebase Articles > Hitachi array do not show RAID Configuration Type for LUNs

Hitachi array do not show RAID Configuration Type for LUNs

Created by Maciej Klasa, last modified by MindTouch on Jun 23, 2016

Views: 782 Votes: 0 Revisions: 3

Overview

RAID Configuration Type for all LUNs on Hitachi Storage Arrays (HDS) do not show any information. In the LUN details page, you can see "-" in LUN details resource.

Environment

  • SRM 6.2.x
  • HDS onboard provider
  • HDS external provider

Cause 

This metric is not supported by Hitachi SMI-S provider.

Resolution

To prove:

1. Gather an SRT recording from the array in question.

2. Find the instance of class HITACHI_StorageVolume where Usage property is not equal to 32769 (Elements with Usage = 32769 are created by the system internally as pool contributors and we will not use them).

3. Check ErrorMethodology if it contains any data. If there is no data, that means RAID type is not supported by the array.

 

Last modified

Tags

Classifications

Public