Join us from the 29th of January to the 2nd of February at Cisco Live 2018 in Barcelona, where we will continue to show how monitoring the network with SolarWinds will keep you ahead of the game. At our booth (WEP 1A), we will demonstrate how SolarWinds network solutions can help. As a bonus, we are also hosting a pre-event webinar - Blame the Network, Hybrid IT Edition with our SolarWinds Head Geek™, Patrick Hubbard on January 24th - GMT (UTC+0): 10:00 a.m. to 11:00 a.m. There's still time to RSVP.

Home > Success Center > Storage Resource Monitor (SRM) > Integration failure with the SRM Orion and SRM Profiler modules

Integration failure with the SRM Orion and SRM Profiler modules

Overview

When integrating SRM Profiler Module and SRM Orion Module, the connection test is successful yet the integration fails. The following error message is received:

Cannot establish communications between Storage Resource Monitor and Storage Profile. See logs for more information.

Environment

All SRM versions

Resolution

Resolve the DNS name for the server hosting the SRM Orion Module from the server hosting the SRM Profiler Module. Update the host file as well on the SRM Profiler Module, mapping the SRM Orion Module server host name with its assigned IP address.

 

Also make sure to use the built in 'admin' account and don't  use a AD/LDAP account. 

 

The Orion Server expects to try to contact the Profiler/STM server using the built in 'admin' account using HTTPS and port 8443 using JSWIS (Java based SolarWinds Information Service as its methodology to connect back to the STM/Profiler server.

 