Submit a ticketCall us

Looking to compare latest NPM features with previous versions of NPM?
The NPM new feature summary offers a comparison of new features and improvements offered with this release.

 

 

 

 

Home > Success Center > Storage Resource Monitor (SRM) > Database Configuration Failed Error while executing script: Multiple invalid column name errors

Database Configuration Failed Error while executing script: Multiple invalid column name errors

Created by Norsolihati Selamat, last modified by Rodim Suarez on Jul 11, 2016

Views: 673 Votes: 0 Revisions: 6

Overview

Upgrade from SRM 6.1 RC to GA fails with the following error on Cionfiguration Wizard logs:
Database Configuration failed:
Invalid column name 'IOLatencyTotal'
Invalid column name 'IOLatencyRead'
Invalid column name 'IOLatencyWrite'
Invalid column name 'IOLatencyOther'
Invalid column name 'IOLatencyTotal'

Invalid column name 'IOLatencyRead'
Invalid column name 'IOLatencyWrite'
Invalid column name 'IOLatencyOther'

Invalid column name 'IOLatencyTotal'

Invalid column name 'IOLatencyRead'
Invalid column name 'IOLatencyWrite'
Invalid column name 'IOLatencyOther'

Environment

SRM 6.1 RC

Resolution

Note: Make sure to backup your database before doing any changes.

  1. Execute the following SQL script that will enable GA Configuration Wizard to update all DB tables:
    IF  EXISTS (SELECT * FROM dbo.sysobjects WHERE id = OBJECT_ID(N'[dbo].[GetSrmDbVersion]') AND xtype in (N'FN', N'IF', N'TF'))
     DROP FUNCTION [dbo].[GetSrmDbVersion]
    GO

    SET ANSI_NULLS ON
    GO
    SET QUOTED_IDENTIFIER ON
    GO

    CREATE FUNCTION [dbo].[GetSrmDbVersion]()
    RETURNS int
    AS
    BEGIN
     RETURN 4 
    END
  2. Rerun the Configuration Wizard.

 

Last modified
19:38, 10 Jul 2016

Tags

Classifications

Public