Submit a ticketCall us

Announcing NCM 7.7
With NCM 7.7, you can examine the rules that make up an access control list for a Cisco ASA device. Then you can apply filters to display only rules that meet the specified criteria, order the rules by line number or by the hit count, and much more.
See new features and improvements.

Home > Success Center > Storage Manager (STM) > SRM Profiler Administrator Guide > Adding storage arrays > HP XP

HP XP

Updated: June 16, 2017

This information is provided 'as-is' as a reference for our customers. SolarWinds provides no guarantees as to the accuracy of this information as the software is built and distributed by 3rd party vendors who may make changes at any time. SolarWinds does not provide official support for problems related to vendor's SMI-S Providers, but customers can seek support via Thwack. Our product team and other knowledgeable customers regularly use these forums and may be able to assist you.

Find details on how to add your HP XP array to SRM Profiler. Below are details about what you need before you begin, instructions on using the Add a Device Wizard, and guidance for resolving the troubleshooting messages you might encounter.

Before you begin

  • The HP XP array requires an SMI-S provider before it can be monitored by SRM Profiler. The HDS provider is part of the HiCommand Device Manager as illustrated in the diagram below.

File:Success_Center/Reusable_content_-_InfoDev/SRM_Profiler/Add_HP_XP/03000053_483x107.png

Provider IP address

IP address of the SMI-S provider

Provider Admin Username

The Administrator Username set up when adding a subsystem to the HiCommand Device Manager

Provider Admin Password

The Administrator Password set when adding a subsystem to the HiCommand Device Manager

  • See the Hitachi Data Systems (HDS) Provider section for details on installing the HDS provider in the HiCommand Device Manager. Or contact your HP XP vendor for HDS SMI-S provider support.
  • Before adding your HP XP array to SRM Profiler, you must collect the information listed in the table below.

Add the array

Use the Add a Device wizard to add your HP XP array to SRM Profiler.

Troubleshoot with the Add a Device wizard

Troubleshoot with the Add a Device wizard provides details and guidance about the error messages you might encounter.

Manual configuration

Use the manual configuration if you must specify parameters that are not available from the Add a Device Wizard.

  1. In step 1 of the Add a Device Wizard , select HP XP.
  2. From the Add a Device – HP XP window, click the Manual Configuration link.
  3. In the Create New Device for Agent: Storage Array window, provide the following information:
    • Server IP Address: From the drop down menu, select the SRM Profiler agent you want to monitor your array.
    • Device Display Name: Enter a meaningful name for your array.
    • Storage Array Type: Set to Storage Array HP XP.
    • Active: Keep this box checked. Clearing this check box stops data collection for your array.
  4. In the Configure Device window, provide the values for the following fields.

    Other parameters are editable from this window. Make changes only if you are sure of a parameter value, otherwise leave the default value.

    • Status: Select On.
    • User Name: Enter the user name used to access the provider. Typically this is the HiCommand Device Manager.
    • Password: Enter the password used to access the provider.
    • Provider IP Address: Enter the IP address of the provider.
    • Identifier: Enter the serial number for the array.
  5. Click Test to test the connectivity between the agent and the array's SMI-S provider. You must enter the username, password, and provider IP before you can test the connection.
  6. Click Save to save the configuration and push it to the agent to begin monitoring the array.
 
Last modified
11:17, 26 Jun 2017

Tags

Classifications

Public