Submit a ticketCall us

Looking to compare latest NPM features with previous versions of NPM?
The NPM new feature summary offers a comparison of new features and improvements offered with this release.

 

Home > Success Center > Storage Manager (STM) > Run an ECOM Service Check for EMC SMI-S

Run an ECOM Service Check for EMC SMI-S

Table of contents

Overview

The following article describes how to check if the EMC-based SMI-S provider is running or needs to be repaired/upgraded to a newer version (or at least to see if it can respond to "Display Version"'). EMC SMI-S providers are sensitive and at short notice it can stop responding.

Environment

STM v5, v5.1, v5.2, v5.2.2, v5.3.3, v5.6.2, v5.7.1 and v6.0

Steps

  1. RDP to the Windows box hosting the SMI-S application.
  2. Navigate to Services.msc and find the entry aptly named: ECOM. This should tie back to: C:\program Files\EMC\ECIM\ECOM\bin\ecom.exe.
  3. Ensure that the Status is Started.
    Note: You can also test the status of the SMI-S provider itself by launching it from C:\program Files\EMC\ECIM\ECOM\bin\. From \bin, there is a test utility named,TestSmiProvider.exe.
  4. Click Enter about seven times or until the cursor is at: <localhost:5988>.
  5. Type ein (stands for Enumerate Instances).
  6. For Class: type cim_computersystem.

    Normal output will show:

    (localhost:5988) ? ein
    Class: cim_computersystem
    ++++ Testing EnumerationInstanceNames: cim_computersystem ++++
    Instance 0:
    Clar_StorageProcessorSystem.CreationClassName="Clar_StorageProcessorSystem",Name
    Instance 1:
    Clar_StorageProcessorSystem.CreationClassName="Clar_StorageProcessorSystem",Name
    Instance 2:
    Clar_StorageSystem.CreationClassName="Clar_StorageSystem",Name="CLARiiON+APM0007
    Instance 3:
    SE_ManagementServer.CreationClassName="SE_ManagementServer",Name="sup-aus-milh-0

    Enumerate 4 instance names; repeat count 1;return data in 0.359375 seconds

    Retrieve and Display data - 1 Iteration(s) In 0.421875 Seconds

  7. Press Enter to continue. You will also be able to do normal things like DISPLAY VERSION: command is dv

    (localhost:5988) ? dv
    ++++ Display version information ++++

    CIM ObjectManager Name: EMC:10.110.6.101

    CIMOM Version: EMC CIM Server Version 2.7.3.3.0.8

    SMI-S qualified version: 1.5.0

    SMI-S Provider version: V4.6.2.3

    SMI-S Provider Location: Proxy

    SMI-S Provider Server:
    Windows_NT sup-aus-milh-02 6.1.7600 x86_64 (64bit Libraries)

    Solutions Enabler version: V7.6-1808 2.8

    Firmware version information:
    (Remote) CLARiiON Array APM00071600268 (Rack Mounted CX3_10_C) : 3.26.10.5.020

    Retrieve and Display data - 1 Iteration(s) In 2.000000 Seconds

  8. Press Enter to continue. If dv cannot provide a response, then the SMI-S provider is not responding. 
  9. Log a support ticket with EMC to determine the cause why the SMI-S provider is not responding.
Last modified
03:47, 23 Jun 2016

Tags

Classifications

Public