Join us from the 29th of January to the 2nd of February at Cisco Live 2018 in Barcelona, where we will continue to show how monitoring the network with SolarWinds will keep you ahead of the game. At our booth (WEP 1A), we will demonstrate how SolarWinds network solutions can help. As a bonus, we are also hosting a pre-event webinar - Blame the Network, Hybrid IT Edition with our SolarWinds Head Geek™, Patrick Hubbard on January 24th - GMT (UTC+0): 10:00 a.m. to 11:00 a.m. There's still time to RSVP.

Home > Success Center > Server & Application Monitor (SAM) > WinRM test failed – Unable to load assembly "-"specified in "InitializationParameters" section

WinRM test failed – Unable to load assembly "-"specified in "InitializationParameters" section

Overview

WinRM test failed – Unable to load assembly "-"specified in "InitializationParameters" section.

Environment

All SAM versions

Resolution

Open PowerShell session in Administrator context.


To view the existing InitializationParameters configuration, type:
Get-ChildItem -Path wsman:\localhost\plugin\microsoft.powershell\InitializationParameters

To remove the assemblyname value, type:
Remove-Item -Path wsman:\localhost\plugin\microsoft.powershell\InitializationParameters\assemblyname

To remove the pssessionconfigurationtypename value, type:
Remove-Item -Path wsman:\localhost\plugin\microsoft.powershell\InitializationParameters\pssessionconfigurationtypename

To restart WinRM service, type the following in a command prompt run in the Administrator context
sc stop WinRM
sc query WinRM
sc start WinRM

 

If the Configure Serve' button continues to fail with the same error, reboot the Exchange server during the next maintenance window and try again.

 