Learn how help desk software can simplify ticketing management, allow you to track hardware and software assets, and accelerate the speed of IT support and service delivery. Gain insights on how remote support tools allow your IT team to maximize their efficiency and ticket resolution by expediting desktop troubleshooting, ultimately helping keep end-users happy and productive.

Register here.

Home > Success Center > Server & Application Monitor (SAM) > Server & Application Monitor (SAM) Getting Started Guide > Reduce alerting noise > Event correlation alerts (Y after X)

Event correlation alerts (Y after X)

Table of contents
No headers
Created by Chris.Moyer_ret, last modified by Anthony.Rinaldi_ret on Aug 23, 2016

Views: 392 Votes: 0 Revisions: 6

You may have some conditions you want to alert on if Y happens after X. For example, you might want to receive an alert if there is a problem with your failover. In this example, if node A goes down, the alert waits 5 minutes, and then checks that node B is up. If node B is not up, the alert is triggered.

Make sure to select a And then after value, which is located between the alert sections.

Then, in the secondary section, configure the actual trigger condition so that Node Name is equal to Node B and Node Status is equal to Down.