Error: The configuration file for the configuration executable was not found on the Orion server.

Cause: This is an internal error. This can be caused by either an incorrect SAM installation, or the SolarWinds.APM.RemoteIISConfigurator.exe.config file was deleted or modified.

Resolution: Add the SolarWinds.APM.RemoteIISConfigurator.exe.config file to the following directory: C:\Program Files (x86)\SolarWinds\Orion\APM. For details, see the log on the Orion server located at: [ALLUSERSPROFILE]\ProgramData\Solarwinds\Logs\APM\RemoteExecutableStarter.log. When complete, rerun the AppInsight for IIS Automatic Configuration Wizard.

 