Troubleshooting a WMI Node issue in SAM

Table of contents
No headers

Updated: 3-9-2017

The following conditions must be met before you can proceed troubleshooting WMI nodes:

  • The node has successfully been added via WMI.
  • WMI is working properly on the remote server.
  • The Hardware Monitoring Agent software is installed on the remote server and running.

When ready, use Wbemtest.exe to troubleshoot WMI:

  1. Open wbemtest.exe, usually located at C:\Windows\System32\wbem\wbemtest.exe.
  2. Connect from the problematic node (either the SAM server or the additional poller server) to the remote server using wbemtest.exe.
  3. Click Connect. In the Namespace field enter:
    • For IBM and HP enter: \\RemoteServerIpAddress\root
    • For Dell enter: \\RemoteServerIpAddress\root\cimv2
      File:Success_Center/Reusable_content_-_InfoDev/SAM_Admin_Guide_Reuse/SAM-Admin-MT/0V0/0Q0/connect9.png
  4. Enter administrator credentials and click Connect.
  5. Once connected, click Query from the main screen. The Query dialog appears.
  6. Enter: select * from __Namespace
    File:Success_Center/Reusable_content_-_InfoDev/SAM_Admin_Guide_Reuse/SAM-Admin-MT/0V0/0Q0/connectq.png
  7. Replace Namespace with the following:
    • For HP nodes, replace Namespace with HPQ
    • For Dell nodes, replace Namespace with Dell
    • For IBM nodes, replace Namespace with IBMSD
  8. If the proper Namespace is found, connect to this Namespace.
    • \\RemoteServerIpAddress\root\IBMSD for IBM.
    • \\RemoteServerIpAddress\root\HPQ for HP.
    • \\RemoteServerIpAddress\root\cimv2\Dell for Dell.
      File:Success_Center/Reusable_content_-_InfoDev/SAM_Admin_Guide_Reuse/SAM-Admin-MT/0V0/0Q0/wmit.png
  9. Run a Query for specific information: Select Manufacturer, Model, SerialNumber from CIM_Chassis
  10. If the test was not successful, re-install the platform or Hardware Monitoring Agent software on the remote server with the latest release.
 